Verilink DIDCSU 2912 (880-502646-001) Product Manual Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware de computador Verilink DIDCSU 2912 (880-502646-001) Product Manual. Verilink DIDCSU 2912 (880-502646-001) Product Manual User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 107
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Verilink DIDCSU 2912
Manual
October 1999
P/N 880-502646-001-E1
PRI
EXT
MANAGEMENT
DIDCSU
2912
1
2
SYS
2
1
LOCAL
NET
DATA
Vista de página 0
1 2 3 4 5 6 ... 106 107

Resumo do Conteúdo

Página 1 - Verilink DIDCSU 2912

Verilink DIDCSU 2912 ManualOctober 1999P/N 880-502646-001-E1PRIEXTMANAGEMENTDIDCSU291212SYS21LOCALNETDATA

Página 2 - Lithium Battery

DIDCSU 2912 Overview1-4Verilink DIDCSU 2912 User ManualThe DIDCSU 2912 does the necessary cross-connections to ensure that the local area network sign

Página 3 - Safety Precautions

DIDCSU E1 Version4-28Verilink DIDCSU 2912 User ManualEach circuit must include a minimum of one network port (circuits are not supported from data por

Página 4 - Publications Staff

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-29NOTE:If a module is moved to a different slot, any circuit previously configured in that module i

Página 5 - Table of Contents

DIDCSU E1 Version4-30Verilink DIDCSU 2912 User ManualManufacturing InfoTo display the firmware versions and CIM types, choose the letter “I” from the

Página 6

IndexVerilink DIDCSU 2912 User Manual Index-1Numerics1/8test pattern 3-20, 4-182N1 5-1test pattern 3-20, 4-182N20-1test patterns 3-20, 4-183 in 24 3-2

Página 7

Index-2 Verilink DIDCSU 2912 User Manualbipolar violations 3-23Cyclic Redundancy Check 3-23, 4-21displaying 3-23, 4-21Extended Superframe Format 3-23F

Página 8

Verilink DIDCSU 2912 User Manual Index-3E1 port configuration 4-7net port alarm 3-26, 4-23performance/status 3-22, 3-24, 4-20, 4-21T1 port configurati

Página 9 - Bypass Mode

Index-4 Verilink DIDCSU 2912 User ManualUUAS 4-22Unavailable Seconds 4-22Vview circuits 3-32, 4-29

Página 10 - Components

VERILINK CORPORATION127 JETPLEX CIRCLEMADISON, ALABAMA 35758TEL: (800) 837-4546October 1999P/N 880-502646-001-E1

Página 11 - Interface

DIDCSU 2912 OverviewVerilink DIDCSU 2912 User Manual1-5Figure 1-2 DIDCSU Front Panel LEDsThe DIDCSU front panel’s System LED (SYS) is green when the m

Página 12 - DIDCSU 2912 Overview

DIDCSU 2912 Overview1-6Verilink DIDCSU 2912 User Manual•External timing source input—The 8-pin mini-DIN connector optionally receives a square wave si

Página 13

DIDCSU 2912 OverviewVerilink DIDCSU 2912 User Manual1-7Figure 1-4 E1 CIM Configurations V. 3 5V.3 5INPUTTIMINGRELAYNO COM NCDATA 2DATA 1CEPTRX TXRX TX

Página 14 - System Cables

DIDCSU 2912 Overview1-8Verilink DIDCSU 2912 User ManualTable 1-2 Data Port Adapter CablesShelf TypesThe DIDCSU 2912 can reside in a Dual-Line shelf (D

Página 15

DIDCSU 2912 OverviewVerilink DIDCSU 2912 User Manual1-91. Network interface cables2. High-speed data application cables3. Primary management cable to

Página 16 - Specifications

DIDCSU 2912 Overview1-10Verilink DIDCSU 2912 User ManualSpecificationsTable 1-3 DIDCSU Specifications Item SpecificationNumber of ports4 per module (

Página 17

DIDCSU 2912 OverviewVerilink DIDCSU 2912 User Manual1-11Table 1-4 CIM Configurations * LP = Lightning Protection (if an E1 CIM does not have an “LP” l

Página 18

DIDCSU 2912 Overview1-12Verilink DIDCSU 2912 User Manual

Página 19 - DIDCSU 2912 Quick Set-Up

Verilink DIDCSU 2912 User Manual2-1Chapter2DIDCSU 2912 Quick Set-UpThis chapter is divided into two main sections. The first section provides step-by

Página 20 - Logging On

iiVerilink DIDCSU 2912 User ManualCopyright NoticeCopyright  1999 Verilink Corporation. All rights reserved.This document does not create any express

Página 21 - Compatibility

DIDCSU 2912 Quick Set-Up2-2Verilink DIDCSU 2912 User ManualTerminal ParametersSet your terminal, or terminal program, to•19.2 kbit/s•8 data bits•no pa

Página 22 - Network Port

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-3Bus Compatibility3. If there is no indication of the DIDCSU in the shelf/slot map on the NC

Página 23

DIDCSU 2912 Quick Set-Up2-4Verilink DIDCSU 2912 User Manual8. Once the bus assignment has been made, reboot the DIDCSU by reseating the front module i

Página 24 - Timing Options

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-5Figure 2-5 T1 Port Configuration Menu Place Ports InService13. In the T1 Port Configuration

Página 25 - Setting Alarm

DIDCSU 2912 Quick Set-Up2-6Verilink DIDCSU 2912 User ManualAllow NetworkOriginated Loops18. Type “NL1”, then “Y” to allow network initiated loops on

Página 26

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-7Data Port Configuration 26. From the Configuration Menu, select option “D” to access the Da

Página 27 - Building Circuits

DIDCSU 2912 Quick Set-Up2-8Verilink DIDCSU 2912 User Manual1. Select “A” from the Main Menu, Figure 2-1, to access the Net Port Alarm Menu. 2. Set the

Página 28 - Second Circuit

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-9Building CircuitsCircuit building is a primary function of the NCM 2000. For general inform

Página 29 - E1 Quick Set-Up

DIDCSU 2912 Quick Set-Up2-10Verilink DIDCSU 2912 User Manual5. Type “SP”, then at the prompt use “1,2”, to specify the shelf and slot address for the

Página 30 - Connect to Craft

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-1116. Type “DP”, then at the prompt use “1,2” for the shelf/slot address. At the next pro

Página 31

Verilink DIDCSU 2912 User Manualiii ATTENTION!Les circuits doivent êtré interconnectés de manière à ce que l’ équipement continue a êtré en agrément a

Página 32

DIDCSU 2912 Quick Set-Up2-12Verilink DIDCSU 2912 User ManualNOTE:These procedures may not match your configuration. Use this chapter as a guide for eq

Página 33 - Failure Alarm

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-13Figure 2-15 NCM Main Menu Bus Compatibility3. If there is no indication of the DIDCSU in t

Página 34

DIDCSU 2912 Quick Set-Up2-14Verilink DIDCSU 2912 User ManualFigure 2-16 DIDCSU Main Menu 7. From the DIDCSU Main Menu, select the letter “O” for Node

Página 35

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-15Figure 2-17 Configuration Menu 12. From the Configuration Menu (Figure 2-17), select optio

Página 36

DIDCSU 2912 Quick Set-Up2-16Verilink DIDCSU 2912 User ManualSelect FASE AlarmCategory16. Type “S1”, then “2” to select Major as the alarm category for

Página 37

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-17Data Port Configuration 24. From the Configuration Menu, select option “D” to access the D

Página 38

DIDCSU 2912 Quick Set-Up2-18Verilink DIDCSU 2912 User Manual1. Select “A” from the Main Menu, Figure 2-16, to access the Net Port Alarm Menu. 2. Set t

Página 39

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-19Building CircuitsCircuit building is a primary function of the NCM 2000. For general infor

Página 40

DIDCSU 2912 Quick Set-Up2-20Verilink DIDCSU 2912 User Manual5. Type “SP”, then at the prompt use “1,2”, to specify the shelf and slot address for the

Página 41 - DIDCSU T1 Version

DIDCSU 2912 Quick Set-UpVerilink DIDCSU 2912 User Manual2-2116. Type “DP”, then at the prompt use “1,2” for the shelf/slot address. At the next pro

Página 42

ivVerilink DIDCSU 2912 User Manual• Do not place this product on an unstable cart, stand, or table. It may fall, causing serious damage to the product

Página 43 - Selection

DIDCSU 2912 Quick Set-Up2-22Verilink DIDCSU 2912 User Manual

Página 44

Verilink DIDCSU 2912 User Manual3-1Chapter3DIDCSU T1 VersionThis chapter describes how to configure and administer the DIDCSU 2912 T1 parameters usin

Página 45 - Administration Menu

DIDCSU T1 Version3-2Verilink DIDCSU 2912 User ManualTerminal ParametersSet your terminal, or terminal program, to• 19.2 kbit/s• 8 data bits•no parity•

Página 46 - Configuration Menu

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-3•The letter surrounded by brackets ( [ ] ) indicates the location of the active module being refer

Página 47 - Configuring the

DIDCSU T1 Version3-4Verilink DIDCSU 2912 User ManualDIDCSU 2912 Main Menu ParametersOnce the DIDCSU module has been selected, the Main Menu commands p

Página 48

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-5Administration MenuUse the Controller Administration Menu to modify and manage system-wide paramet

Página 49 - FDL Configuration

DIDCSU T1 Version3-6Verilink DIDCSU 2912 User ManualTable 3-3 Administration Menu Parameters Configuration MenuUse the Configuration Menu to configure

Página 50

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-7Configuring the T1 PortTo access the T1 Port Configuration Menu, enter “P” from the Configuration

Página 51

DIDCSU T1 Version3-8Verilink DIDCSU 2912 User ManualLn Line Coding: Use this option to choose Alternate Mark Inversion (AMI) or Bipolar Eight-Zero Sub

Página 52

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-9When you are finished configuring the T1 network ports, enter “X” to return to the Configuration M

Página 53

Table of ContentsVerilink DIDCSU 2912 User Manual vDIDCSU 2912 Overview...

Página 54

DIDCSU T1 Version3-10Verilink DIDCSU 2912 User ManualTable 3-5 FDL Configuration MenuCommand Description OptionsSn FDL Standard: Specify if you want t

Página 55 - Figure 3-10 Loopbacks

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-11Timing OptionsEnter “T” from the T1 Port Configuration Menu to display the Timing Options Menu:Fi

Página 56

DIDCSU T1 Version3-12Verilink DIDCSU 2912 User ManualTable 3-6 Configuration Menu (Timing Options) Parameters Command Description OptionsR Receive Clo

Página 57

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-13If you enable Receive clock from shelf, the Timing Options Menu changes: Figure 3-8 Timing Option

Página 58 - Diagnostics Menu

DIDCSU T1 Version3-14Verilink DIDCSU 2912 User ManualType “X” again to return to the Configuration Menu (Figure 3-4).Data Port Configuration MenuTo ac

Página 59

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-15•LLB—Local Loopback•TM—Test ModeDuring normal operation, these leads should be set to LOW. By con

Página 60 - T1 Port Diagnostics Menu

DIDCSU T1 Version3-16Verilink DIDCSU 2912 User Manual•The number of errors detected by the test are displayed by the Error Test Counter.Table 3-8 Data

Página 61 - Diagnostics

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-17SSn Clear to Send (CTS): This is a DCE output. LOW indicates the lead is off (negative voltage).

Página 62 - Performance/Status Menu

DIDCSU T1 Version3-18Verilink DIDCSU 2912 User ManualDiagnostics MenuThe diagnostics menu is used for troubleshooting the network and data ports. To a

Página 63

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-19Table 3-9 T1 Port Diagnostics MenuCommand Description OptionsLn Line Loopback (LLB): A loopback

Página 64

viVerilink DIDCSU 2912 User ManualDIDCSU T1 Version...

Página 65 - Threshold Status

DIDCSU T1 Version3-20Verilink DIDCSU 2912 User ManualTn Test Pattern: Use this option to indicate one of the following options:• None: This option ind

Página 66 - Net Port Alarm Menu

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-21Data Port Diagnostics MenuFor diagnostics on the data port, enter “P” to access the Data Port Dia

Página 67 - Threshold

DIDCSU T1 Version3-22Verilink DIDCSU 2912 User ManualPerformance/Status MenuThe Performance/Status Menu is used to monitor the functioning and conditi

Página 68

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-23•BER—Bit Error Rate.•CGA—Carrier Group AlarmEnter “C” to access the Counter Menu. These counts ar

Página 69 - Display Alarm

DIDCSU T1 Version3-24Verilink DIDCSU 2912 User ManualFigure 3-16 24 hr T1 Performance Data Summary Following is a brief description of the 24 hr T1 Pe

Página 70

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-25Net Port Alarm Threshold Status MenuEnter “T” from the Performance/Status Menu to access the Net

Página 71 - C1: Timeslots 1-15

DIDCSU T1 Version3-26Verilink DIDCSU 2912 User ManualFigure 3-17 Net Port Alarm Threshold Status MenuWhen finished reviewing the performance/status in

Página 72

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-27Table 3-13 Net Port Alarm Menu ParametersNet Port AlarmThresholdConfigurationMenuThe Performance/

Página 73 - DIDCSU E1 Version

DIDCSU T1 Version3-28Verilink DIDCSU 2912 User ManualFigure 3-19 Net Port Alarm Threshold Configuration MenuNOTE:To disable any or all alarm condition

Página 74

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-29Display Alarm BuffersTo display the alarm buffer, enter the letter “O” in the Net Port Alarm Menu

Página 75

Verilink DIDCSU 2912 User Manual1-1Chapter1DIDCSU 2912 OverviewThis manual describes the DIDCSU 2912, a Dual Integrated Data Service Unit/Channel Serv

Página 76

DIDCSU T1 Version3-30Verilink DIDCSU 2912 User ManualFigure 3-20 Display Alarm BufferWhen finished reviewing the alarm information, enter “X” to retur

Página 77

DIDCSU T1 VersionVerilink DIDCSU 2912 User Manual3-31Figure 3-22 Circuit Build Configuration MenuTable 3-15 Circuit Build Configuration Menu Parameter

Página 78

DIDCSU T1 Version3-32Verilink DIDCSU 2912 User ManualNOTE:To cross-connect DIDCSU circuits across the AS2000 backplane to other DIDCSU modules an NCM

Página 79

Verilink DIDCSU 2912 User Manual4-1Chapter4DIDCSU E1 Version This chapter describes how to configure and administer the DIDCSU 2912 E1 parameters usin

Página 80

DIDCSU E1 Version4-2Verilink DIDCSU 2912 User ManualTerminal ParametersSet your terminal, or terminal program, to:• 19.2 kbit/s• 8 data bits•no parity

Página 81

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-3•Slots containing DIDCSU modules display an A at the intersection of rows and columns designating

Página 82 - Auto Restore

DIDCSU E1 Version4-4Verilink DIDCSU 2912 User ManualDIDCSU 2912 Main Menu ParametersOnce the DIDCSU module has been selected, the Main Menu commands p

Página 83

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-5Administration MenuUse the Controller Administration Menu (Administration Menu) to modify and mana

Página 84

DIDCSU E1 Version4-6Verilink DIDCSU 2912 User ManualI Change Site Name—Use this option to specify the site name for the DIDCSU. All reports will conta

Página 85

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-7Configuration MenuUse the Configuration Menu to configure your E1 port, data port, or timing optio

Página 86

DIDCSU 2912 Overview1-2Verilink DIDCSU 2912 User ManualThe aggregate data rate from terminal equipment can be up to one of the following:Table 1-1 Dat

Página 87

DIDCSU E1 Version4-8Verilink DIDCSU 2912 User ManualTable 4-4 E1 Port Configuration Menu ParameterCommand Description OptionsIn In Service: Use this

Página 88

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-9Timing OptionsEnter “T” from the E1 Port Configuration Menu to display the Timing Options Menu:Fig

Página 89

DIDCSU E1 Version4-10Verilink DIDCSU 2912 User Manualsecondary source remains the timing source until you manually reconfigure the primary source, or

Página 90

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-11If you enable Receive clock from shelf, the Timing Options Menu changes: Figure 4-7 Timing Option

Página 91 - Data Port Diagnostics Menu

DIDCSU E1 Version4-12Verilink DIDCSU 2912 User ManualData Port Configuration MenuTo access the Data Port Configuration Menu (Figure 4-8), enter “D” fr

Página 92 - Performance / Status Menu

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-13During normal operation, these leads should be set to LOW. By connecting a test set to the data p

Página 93

DIDCSU E1 Version4-14Verilink DIDCSU 2912 User ManualTable 4-7 Data Port Configuration Menu Parameters Command Description OptionsIn In Service: Use t

Página 94

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-15Diagnostics MenuThe diagnostics menu is used for troubleshooting the network and data ports. To a

Página 95

DIDCSU E1 Version4-16Verilink DIDCSU 2912 User ManualFigure 4-11 E1 Port Diagnostics Menu-- DIDCSU 2912 E1 PORT DIAGNOSTICS MENU ---- DIDCSU 2912 E1

Página 96

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-17Table 4-8 E1 Port Diagnostics MenuCommand Description OptionsLn Line Loopback (LLB): A loopback

Página 97

DIDCSU 2912 OverviewVerilink DIDCSU 2912 User Manual1-3CSU/DSUThe DIDCSU 2912 can be used in a simple configuration in which it functions as two T1 or

Página 98

DIDCSU E1 Version4-18Verilink DIDCSU 2912 User ManualData Port Diagnostics MenuFor diagnostics on the data port, enter “P” to access the Data Port Dia

Página 99 - Circuit Manager Menu

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-19Figure 4-12 Data Port Diagnostics MenuTable 4-9 Data Port Diagnostics Menu Parameters-- DIDCSU

Página 100

DIDCSU E1 Version4-20Verilink DIDCSU 2912 User ManualPerformance / Status MenuThe Performance/Status Menu is used to monitor the functioning and condi

Página 101 - C1: Timeslots 1-16

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-21Enter C to access the Counter Menu. These counts are continuous until reset manually using the Rn

Página 102 - Manufacturing Info

DIDCSU E1 Version4-22Verilink DIDCSU 2912 User ManualFollowing is a brief description of the Performance/Status Menu (24 hr E1 Performance Data Summar

Página 103 - Numerics

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-23Figure 4-16 Net Port Alarm Threshold Status MenuWhen finished reviewing the performance/status in

Página 104

DIDCSU E1 Version4-24Verilink DIDCSU 2912 User ManualTable 4-13 Net Port Alarm Menu ParametersNet Port AlarmThresholdConfigurationMenuThe Performance/

Página 105

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-25alarm condition and the first second of the next interval is also errored. The alarm state contin

Página 106 - Index-4

DIDCSU E1 Version4-26Verilink DIDCSU 2912 User ManualTable 4-14 Net Port Alarm Threshold Configuration Menu ParametersCommand Description OptionsPnDnA

Página 107 - P/N 880-502646-001-E1

DIDCSU E1 VersionVerilink DIDCSU 2912 User Manual4-27Display Alarm BuffersTo display the alarm buffer, enter the letter “O” in the Net Port Alarm Menu

Comentários a estes Manuais

Sem comentários