PRISM 3000 Configuration Guide
TRANSPORT
®
Customer Location: ________________________________________
Circuit ID: ________________________________________
Date: ______ / ______ / ______
T1 NET CONFIGURATION
Framing Type: ESF D4
Line Coding: AMI B8ZS
Line Build Out: 0dB -7.5dB -15dB -22.5dB
Timing: INTERNAL NETWORK T1 DTE STATION
PORT 1 PORT 2 PORT 3 PORT 4
Station Input Timing: 1.544MHz Nx56K Nx64K
(Timing must be set to ‘Station’ in ‘Timing menu’)
Station Timing: ______ Enter a number from 1 to 24 to select the
‘N’ multiplier for the ‘Station Input Timing’ menu.
Zero Suppression: ENABLE DISABLE
PRM Enable: ENABLE DISABLE
Alarm Thresholds: ALARM RESET:___ ES:___ SES:___
(enter # of seconds) LOSS:___
OOFS:___ UAS:___
RAS:___ AISS:___ BPVS:___
T1 DTE CONFIGURATION
(Optional)
Framing Type: ESF D4
Line Coding: AMI B8ZS
DSX Level (feet): 0-110 111-220 221-330 331-440
441-550 551-660 >660
Channel Assignment: IDLE THRU REM COM PORT 1
PORT 2 PORT 3 PORT 4
DTE PORT 1
Port Rate Multiplier: Nx64K Nx56K DISABLE
Port Rate: ______ Enter a number from 0 to 24 to select the
‘N’ multiplier for the ‘Port Rate Multiplier’ menu.
Starting Channel #: ______ Enter a number from 1 to 24.
DS0 Channel Assign: CONTIGUOUS ALTERNATING
Port Transmit Clock: INTERNAL EXTERNAL OVERSAMPLED
Invert Data: NO YES
CTS Control: INTERNAL FORCE TRUE FORCE FALSE
DSR Control: INTERNAL FORCE TRUE FORCE FALSE
DCD Control: INTERNAL FORCE TRUE FORCE FALSE
V.54 Loop: ENABLE DISABLE
RS232 Port Rate: NONE SYNCHRONOUS 1200 2400
(optional) 4800 9600 14400 19200 28800
38400 48000 56000 64000
DTE PORT 2
Port Rate Multiplier: Nx64K Nx56K DISABLE
Port Rate: ______ Enter a number from 0 to 24 to select the
‘N’ multiplier for the ‘Port Rate Multiplier’ menu.
Starting Channel #: ______ Enter a number from 1 to 24.
DS0 Channel Assign: CONTIGUOUS ALTERNATING
Port Transmit Clock: INTERNAL EXTERNAL OVERSAMPLED
Invert Data: NO YES
CTS Control: INTERNAL FORCE TRUE FORCE FALSE
DSR Control: INTERNAL FORCE TRUE FORCE FALSE
DCD Control: INTERNAL FORCE TRUE FORCE FALSE
V.54 Loop: ENABLE DISABLE
DTE PORT 3
Port Rate Multiplier: Nx64K Nx56K DISABLE
Port Rate: ______ Enter a number from 0 to 24 to select the
‘N’ multiplier for the ‘Port Rate Multiplier’ menu.
Starting Channel #: ______ Enter a number from 1 to 24.
DS0 Channel Assign: CONTIGUOUS ALTERNATING
Port Transmit Clock: INTERNAL EXTERNAL OVERSAMPLED
Invert Data: NO YES
CTS Control: INTERNAL FORCE TRUE FORCE FALSE
DSR Control: INTERNAL FORCE TRUE FORCE FALSE
DCD Control: INTERNAL FORCE TRUE FORCE FALSE
V.54 Loop: ENABLE DISABLE
RS232 Port Rate: NONE SYNCHRONOUS 1200 2400
(optional) 4800 9600 14400 19200 28800
38400 48000 56000 64000
DTE PORT 4
Port Rate Multiplier: Nx64K Nx56K DISABLE
Port Rate: ______ Enter a number from 0 to 24 to select the
‘N’ multiplier for the ‘Port Rate Multiplier’ menu.
Starting Channel #: ______ Enter a number from 1 to 24.
DS0 Channel Assign: CONTIGUOUS ALTERNATING
Port Transmit Clock: INTERNAL EXTERNAL OVERSAMPLED
Invert Data: NO YES
CTS Control: INTERNAL FORCE TRUE FORCE FALSE
DSR Control: INTERNAL FORCE TRUE FORCE FALSE
DCD Control: INTERNAL FORCE TRUE FORCE FALSE
V.54 Loop: ENABLE DISABLE
SNMP CONFIGURATION
(Optional)
Unit I.P. Address:
________ . ________ . _______
Router I.P. Address:
________ . ________ . _______
Trap I.P. Address:
________ . ________ . _______
Read Community:
_____________________________
Write Community:
_____________________________
System Contact:
_____________________________
System Name:
_____________________________
System Location:
_____________________________
DIAGNOSTICS
T1 Network Loop: NONE LOOP FAR UNLOOP FAR PLB
LLB NET MLB DTE MLB
T1 DTE Loop: NONE LLB
Port ___ Loop: NONE NEAR SEND LOOP SEND UNLOOP
BERT Function:
BERT Port: NONE NETWORK T1 DTE PORT 1
PORT 2 PORT 3 PORT 4
BERT Channel: ALL IDLE CHANNEL ____ (from 1 to 24)
BERT Pattern: 1 in 8 3 in 24 ALT CLEAR QRSS 63
511 2047 2
15
-1 2
20
-1 2
23
-1
BERT Direction: TOWARD NETWORK TOWARD DTE
SYSTEM UTILITIES
Edit Password: ____________________ (up to 10 characters)
NMS Address: __________ (select a number from 1 to 250)
NMS Bit Rate: 19200 9600 4800 2400 1200
Supv Bit Rate: 19200 9600 4800 2400 1200
Boot Mode: LOCAL NMS
Alarm Cut Off: DISABLE ENABLE
Remote Link: FDL NONE CHANNEL ___ (from 1 - 24)
Call on Alarm:
Primary #: ____________________ (up to __ characters)
Secondary #: ____________________ (up to __ characters)
Element ID: ____________________ (up to 29 characters)
Alarm Notification: OFF DIRECT DIAL DIAL NMS