PRISM 3301 MIB
35
t3DatalinkConfig
{ 1.3.6.1.4.1.425.2.8.1.2 } This table defines the PRISM 3301 Datalink
Configuration, Status, and Control Objects.
t3DteConfig
{ 1.3.6.1.4.1.425.2.8.1.3 } This table defines the PRISM 3301 DTE Configuration,
Status, and Control Objects.
Object Name Object ID User Access Object Description
t3DatalinkIndex t3DatalinkConfigEntry 1 read-write The value for this object is equal to the value of IfIndex from the
Interfaces table of MIB II (RFC 1213).
t3DatalinkEIC t3DatalinkConfigEntry 2 read-write A string containing the Equipment Identification Code (10 characters
maximum).
t3DatalinkLIC t3DatalinkConfigEntry 3 read-write A string containing the Location Identification Code (11 chrs max).
t3DatalinkFIC t3DatalinkConfigEntry 4 read-write A string containing the Frame Identification Code (10 chrs max).
t3DatalinkUIC t3DatalinkConfigEntry 5 read-write A string containing the Unit Identification Code (6 chrs max).
t3DatalinkPID t3DatalinkConfigEntry 6 read-write A string containing the Path Identification (38 chrs max).
t3DatalinkISID t3DatalinkConfigEntry 7 read-write A string containing the Idle Signal Identification (38 chrs max).
t3DatalinkTSID t3DatalinkConfigEntry 8 read-write A string containing the Test Signal Identification (38 chrs max).
t3FarEndISID t3DatalinkConfigEntry 9 read-only A string containing the Far End Idle Signal Identification.
t3FarEndTSID t3DatalinkConfigEntry 10 read-only A string containing the Far End Test Signal Identification.
t3Terminal t3DatalinkConfigEntry 11 read-write The type of terminal.
1 - DTE
2 - Carrier
Object Name Object ID User Access Object Description
t3DteIndex t3DteConfigEntry 1 read-only The value for this object is equal to the value of IfIndex from the Interfaces
table of MIB II (RFC 1213).
t3DteRate t3DteConfigEntry 2 read-write HSSI data rate. Only r3158 and r6316 should be written.
1 - r3158 (3.158 MHz)
2 - r6316 (6.316 MHz)
3 - r12631 (12.631 MHz)
4 - r18947 (18.947 MHz)
5 - r25263 (25.263 MHz)
6 - r31578 (31.578 MHz)
7 - r37894 (37.894 MHz)
8 - r44210 (44.210 MHz)
t3DteCA t3DteConfigEntry 3 read-write This object is bit mapped. When the bit is set it is On, and Off when the bit
is clear.
1 - Turn CA On/Off during LOS
2 - Turn CA On/Off during OOF
4 - Turn CA On/Off during RXAIS
8 - Turn CA On/Off during RXYELLOW
This object can represent multiple setting simultaneously.
t3DteLoopback t3DteConfigEntry 4 read-write This variable represents the loopback configuration of the PRISM 3301's
DTE interface.
1 - t3DteNoLoop - Not in the loopback state
2 - t3LocalDteLoop - DTE port is currently looped at the DTE interface
3 - t3LocalLineLoop - The DTE port is currently looped at the T3 interface
t3DteStatus t3DteConfigEntry 5 read-write This object is bit mapped. When the bit is set, it is On and Off when the bit
is clear. The various bit positions are as follows.
1 - On if NO DTE alarms active
2 - On during DTE CLOCK LOSS
4 - On during other DTE alarm
8 - On if any DTE loopback is active
This object can represent multiple settings simultaneously.