iWANsuite® 5260/5230Reference ManualApril 200234-00304.F

Página 2 - WANsuite 5260/5230

x WANsuite 5260/5230Appendix B SNMP AgentIntroduction ...

Página 3

3-70 WANsuite 5260/5230The TCP Details screen (Figure 3.59) lists the index number, the endpoint name, the TCP local port number, and whether or not t

Página 4

Web Server Interface 3-71Figure 3.60NAT Details ScreenEnableEnables or disables NAT. Default is “Disable.”ModeSelects the Network Address Port Transla

Página 5 - Table of Contents

3-72 WANsuite 5260/5230IP Entry TimerThe maximum time (in seconds) NAT will use resources when not using TCP, UDP, or ICMP.Values: 0−65535Default: 120

Página 6

Web Server Interface 3-73Static TCP Translation Table ScreenThe Static TCP Translation Table screen (Figure 3.61) allows static mapping of global TCP

Página 7 - Chapter 4 VT100 Interface

3-74 WANsuite 5260/5230Static UDP Translation Table ScreenThe Static UDP Translation Table screen (Figure 3.64) allows static mapping of global UDP Se

Página 8

Web Server Interface 3-75NAT Ports ScreenThe parameters on the NAT Ports screen (Figure 3.65) define the NAT global/Internet and local/Corporate ports

Página 9 - Appendix A Specifications

3-76 WANsuite 5260/5230Figure 3.66NAT Port Details ScreenThe NAT Port Details screen provides the following user-activated buttons: The NAT Port Statu

Página 10 - Appendix B SNMP Agent

Web Server Interface 3-77Dynamic Host Configuration Protocol (DHCP)DHCP provides a mechanism through which computers using TCP/IP can obtain protocol

Página 11 - About this Manual

3-78 WANsuite 5260/5230TTLTime to Live for any DHCP packet. Default is 64.Service TypeType of Service used by the DHCP Server packet. Default is 1.Lea

Página 12 - • Diagnostic error messages

Web Server Interface 3-79Figure 3.69DHCP Hosts Screen Host NameThe name of the DHCP Server. Default is none.The DHCP Hosts screen provides the followi

Página 13 - Returning a Unit to Verilink

Preface xiCHAPTER 0PREFACEAbout this ManualThis reference guide for the Verilink WANsuite 5260/5230 intelligent integrated access device (I2AD) descri

Página 14

3-80 WANsuite 5260/5230Host NameName given to the DHCP client.The Static Entries screen provides the following user-activated buttons: IP Address List

Página 15 - 5260/5230

Web Server Interface 3-81Figure 3.72IP Address Status ScreenMAC AddressMAC Address of this DHCP client.IP AddressIP Address given to this DHCP client

Página 16 - 1-2 WANsuite 5260/5230

3-82 WANsuite 5260/5230Figure 3.73Software Upgrade Screen To upgrade the unit’s software, perform the following steps:1 Click the “SW Upgrade” link on

Página 17 - SNMP Management

Web Server Interface 3-83Figure 3.74Countdown ScreenSave/UploadThe Save/Upload screen (Figure 3.75) lets you save a new configuration or upload a form

Página 18 - About FrameStart Technology

3-84 WANsuite 5260/5230entering the new password in both these fields, click the “Change Password” button to update and establish the new password.NOT

Página 19 - Features Summary

Web Server Interface 3-85Figure 3.78Frame Relay Network If the remote units are required to have an IP address for Networks that are different from th

Página 21 - Front Panel

VT100 Interface 4-1C HAPTER4CHAPTER 4VT100 INTERFACEIntroductionThis chapter describes the menus and options associated with the WANsuite 5260/5230’s

Página 22 - Indicator Description

4-2 WANsuite 5260/5230Figure 4.1VT100 Terminal Screen ComponentsCursor ControlsThe VT100 interface uses a blinking cursor to select various menus and

Página 23 - Rear Panel Connections

VT100 Interface 4-3choices. Each time the Spacebar is pressed, a new item appears. When the item you wish to choose is displayed, press the “Esc” key

Página 24 - Ethernet LED Indicators

xii WANsuite 5260/5230and all the connector pin assignments for the interfaces on the back of the WANsuite 5260/5230 unit.• Appendix B, SNMP Agent – T

Página 25 - Power Connection

4-4 WANsuite 5260/5230System ScreenThe first option on the Main menu screen is the System screen (Figure 4.3). This screen lets you view and set speci

Página 26 - Power Failure

VT100 Interface 4-5The System screen displays the user-selectable prompts listed below. Maintenance ResetSelect this prompt to access a screen (Figure

Página 27 - NSTALLATION

4-6 WANsuite 5260/5230Figure 4.5Confirmation Screen NOTICE: Performing a “Maintenance Reset” or a “Save and Restart” will terminate communications wi

Página 28 - Installation Wizard

VT100 Interface 4-7Figure 4.6WANsuite 5260 Interfaces Screen From the WANsuite 5260 Interfaces screen, you may choose from the following: Network 1, N

Página 29 - Installation 2-3

4-8 WANsuite 5260/5230Figure 4.8Network 2 ScreenFunction (Network 2Only)In the Slaved function, Network 2 is slaved and can only be mapped to Network

Página 30 - 2-4 WANsuite 5260/5230

VT100 Interface 4-9“Function” parameter (on the Network 2 Config screen) in Network mode − Internal, Network 1, Serial 1Network 2 (5260)“Function” par

Página 31 - NTERFACE

4-10 WANsuite 5260/5230SESSets the Severely Errored Seconds (SES) threshold. An SES is a 1-second period in which at least 320 CRC errors or one Out-o

Página 32 - Layout of Interface Screens

VT100 Interface 4-11Performance ScreensThe “Performance” prompt near the bottom of the Network screens displays a Performance 24 Hour screen (Figure 4

Página 33 - Figure 3.1

4-12 WANsuite 5260/5230Figure 4.10Performance 30 Day Screen Serial ScreensThe WANsuite 5260 Serial 1 and Serial 2 screens or Serial screen on the WANs

Página 34 - Figure 3.3

VT100 Interface 4-13NOTICE: V.35 requires the use of an optional cable. Refer to Optional Equipment on page A-6 for ordering information.ModeBy defau

Página 35 - Network Screens

Preface xiiiTelephoneCustomer support is available by telephone 24 hours a day, 7 days a week. To speak directly with a Verilink customer service repr

Página 36 - 3-6 WANsuite 5260/5230

4-14 WANsuite 5260/5230# of ChannelsSpecifies the number of channels to be assigned to the DTE.Channel RateThe unit can operate at any data rate that

Página 37 - Web Server Interface 3-7

VT100 Interface 4-15V54Selecting “Enable” allows the unit to respond to in-band V.54 loop codes. If you select “Disable,” the unit ignores these codes

Página 38 - Figure 3.5

4-16 WANsuite 5260/5230FormatSelects the port’s operating mode.Values: Sync, AsyncDefault: SyncFlow ControlSelects the type of flow control to be used

Página 39 - Performance 24 Hour Screen

VT100 Interface 4-17Gateway IP AddressIP address of the default gateway (router) on the LAN side of the unit.DHCP ClientIf DHCP Client is enabled at p

Página 40

4-18 WANsuite 5260/5230ParitySets the parity bit.Values: None, Odd, EvenDefault: NoneStop BitSelects the number of bits required to end the character.

Página 41 - Web Server Interface 3-11

VT100 Interface 4-19Figure 4.14Service Table ScreenThe Service Table screen displays the available services listed by Index number. From this screen,

Página 42 - 3-12 WANsuite 5260/5230

4-20 WANsuite 5260/5230Virtual interface, you must supply an endpoint over which to send PPP encapsulated data, and that endpoint must be for a Frame

Página 43 - Current Pin Status

VT100 Interface 4-21Alarm Reset Timer(sec)Number of seconds that an alarm condition must not be present before an alarm is reset. Zero (0) indicates t

Página 44 - Button Function

4-22 WANsuite 5260/5230Figure 4.17Channel Table Details Screen The Channel Table Details screen lets you establish the Rate, Service, and Idle Pattern

Página 45 - Figure 3.10

VT100 Interface 4-23Figure 4.19DS0 Monitor 30 Day History ScreenThe DS0 Monitor 24 Hour History and 30 Day History screens show the following statisti

Página 46 - Supervisory Screen

xiv WANsuite 5260/5230The address for you to use when returning a unit to Verilink will be provided when the RMA is issued. The standard delivery meth

Página 47 - Adding a Service

4-24 WANsuite 5260/5230Figure 4.20Frame Relay Service Details Screen The Frame Relay Service Details screen displays Service, Pair, and Interface deta

Página 48

VT100 Interface 4-25Once it discovers the link management type, the unit should be set to the discovered value so that subsequent unit or network re-i

Página 49 - Delete Service Button

4-26 WANsuite 5260/5230network side to gather statistics and to perform CIR enforcement, if required. If a DLCI is configured with an Excess Burst dif

Página 50

VT100 Interface 4-27changes state, provided at least one destination IP address for trap is configured in the SNMP configuration.Values: Disable, Enab

Página 51 - Figure 3.16

4-28 WANsuite 5260/5230Figure 4.21 Frame Relay Statistics ScreenTo view the Port Statistics (Figure 4.22) for a specific interval, select that interva

Página 52 - Figure 3.18

VT100 Interface 4-29ReceiveFramesNumber of frames received by the port.OctetsNumber of octets received by the port.Mgmt FramesNumber of management fra

Página 53 - Figure 3.19

4-30 WANsuite 5260/5230ACCMThe Asynchronous Control Character Map (ACCM) configuration option provides a method to negotiate the use of control charac

Página 54 - 3-24 WANsuite 5260/5230

VT100 Interface 4-31CHAP SecretEnter the Secret (i.e., password) necessary to challenge the peer. Values: (User Established)Default: SecretInitiate Ne

Página 55 - Web Server Interface 3-25

4-32 WANsuite 5260/5230Figure 4.24PPP Statistics ScreenPeriodSelects the interval (Current, Summary, or numbered Interval) to be viewed on the PPP Sta

Página 56 - Status and Alarms Table

VT100 Interface 4-33Figure 4.25PAP Table Screen To change the username and password for a selected PAP Index, access the PAP Details screen by selecti

Página 57

About the WANsuite 5260/5230 1-1C HAPTER1CHAPTER 1ABOUT THE WANSUITE5260/5230IntroductionThe telecommunications network service market is rapidly chan

Página 58 - SCADA Details Screen

4-34 WANsuite 5260/5230To change the Username and Secret for a selected CHAP Index, enter the new information in the appropriate field(s) and press th

Página 59 - Figure 3.22

VT100 Interface 4-35Figure 4.28SCADA Device ListPress “Enter” after selecting the device number to display the SCADA Device Details (Figure 4.29) menu

Página 60

4-36 WANsuite 5260/5230ApplicationsSelect “Applications” in the Main Menu screen to display the various WANsuite 5260/5230 applications (Figure 4.30)

Página 61 - Web Server Interface 3-31

VT100 Interface 4-37Figure 4.31Endpoint Table Screen You can add an endpoint in the Add Endpoint field and, when the screen refreshes, you will be abl

Página 62 - Parameters To Negotiate

4-38 WANsuite 5260/5230changed Name parameter will cause the endpoint entry and its corresponding DLCI entry to be saved in the configuration database

Página 63

VT100 Interface 4-39WANsuite 5260/5230 unit here. This DLCI can be used for management only, or for management and actual data. If this parameter is s

Página 64

4-40 WANsuite 5260/5230Figure 4.33DLCI Details Screen The unit uses the first three configuration parameters (Protocol Encapsulation, Proprietary Traf

Página 65 - CHAP Table

VT100 Interface 4-41Bc (bps)If CIR enforcement is configured to “Yes,” the unit will throttle the Committed Burst down to this value (in bits per seco

Página 66

4-42 WANsuite 5260/5230Round Trip DelaySpecifies the frame size (in bytes) of packets making round-trip.Round Trip RateSpecifies the rate (in seconds)

Página 67

VT100 Interface 4-43DLCI Statistics ScreenSelecting “DLCI Statistics” on the Endpoint DLCI Details screen will display the screen shown below in Figur

Página 68 - 3-38 WANsuite 5260/5230

1-2 WANsuite 5260/5230routes. After building the routing tables, WANsuite periodically broadcasts the contents to neighboring routers so that your net

Página 69

4-44 WANsuite 5260/5230Figure 4.35DLCI Statistics Details ScreenThe DLCI Statistics screen in the preceding figure shows a summary that includes all 9

Página 70

VT100 Interface 4-45Service Aware ScreenThe Service Aware function recognizes IP traffic on the WAN and counts the number of frames and bytes passed f

Página 71 - Web Server Interface 3-41

4-46 WANsuite 5260/5230Figure 4.38Rule Config Screen The paragraphs below describe the rule configuration parameters and their options.ServiceSelects

Página 72

VT100 Interface 4-47Filter By IP PortEnables or disables filtering of the IP traffic by the IP port specified in the IP Port field.Tx Alarm ThresholdS

Página 73

4-48 WANsuite 5260/5230CurrentReports on the current 15-minute interval.Interval 1,Interval 2,...,Interval 96Reports on Intervals 1-96, which correspo

Página 74

VT100 Interface 4-49can see if any port is under test, and if so, view the results. You may change Diagnostic parameters on the Test Details screen (F

Página 75

4-50 WANsuite 5260/5230Figure 4.42Network Interface Test Details Screen BERT Table on the Network Interface Test Details ScreenThe BERT table lets you

Página 76

VT100 Interface 4-51“No Sync” is displayed. If the receiver is in pattern sync, “In Sync” is displayed. Elapsed TimeDisplays the time elapsed since a

Página 77 - Figure 3.37

4-52 WANsuite 5260/5230 SettingDisplays the bandwidth on which you wish to perform the BERT. The available values for this parameter depend on which i

Página 78

VT100 Interface 4-53Test Details screens provide the following user-selectable prompts: Trap Log ScreenThe Trap Log screen (Figure 4.44) shows a colle

Página 79

About the WANsuite 5260/5230 1-3Verilink’s FrameStart™ technology is standard with the WANsuite 5260/5230 and benefits the initial installation of fra

Página 80

4-54 WANsuite 5260/5230Figure 4.45Top Talkers Screen To generate a Top Talkers report, enter the duration parameters and desired report size in the av

Página 81

VT100 Interface 4-55frames, and Tx octets that have been passed across it. In addition, the Timestamp field indicates the time at which a packet was e

Página 82

4-56 WANsuite 5260/5230RIP Trust NeighborsGlobally enables the trusted neighbors feature. If there is a list of trusted neighbors in an IP Gateway, on

Página 83

VT100 Interface 4-57Figure 4.47Circuit Table Screen Circuit Details ScreenAccess this menu by selecting the appropriate <Index> number from the

Página 84 - Top N Details Screen

4-58 WANsuite 5260/5230CostRepresents the relative time of treatment of an IP packet. This value is used when there are multiple routes to the same de

Página 85

VT100 Interface 4-59OSPF Auth KeyWhen configured, this parameter allows an authentication procedure to be executed on the OSPF header. If the 64-bit (

Página 86

4-60 WANsuite 5260/5230Figure 4.50Routes Details ScreenEndpointEndpoint name (or interface) through which to send the IP packet to reach the

Página 87 - Circuits Screen

VT100 Interface 4-61Figure 4.51Dynamic Route Table Screen The Dynamic Route Table displays the fields listed below. Static ARP Table ScreenARP (Addres

Página 88

4-62 WANsuite 5260/5230Figure 4.52Static ARP Table Screen The fields listed below are displayed on the Static ARP Table screen. ARP Details ScreenAcce

Página 89

VT100 Interface 4-63EndpointEndpoint name (or Interface) through which to send the IP packet to reach the defined IP Address. The default is the LAN.I

Página 90 - Route Details Screen

1-4 WANsuite 5260/5230Optional Advanced Network ManagementAs an option for the WANsuite 5260/5230, Verilink offers a network management system based o

Página 91 - Figure 3.48

4-64 WANsuite 5260/5230Figure 4.55Area Table ScreenThe fields displayed on the Area Table screen are described below. Area Details ScreenThis screen d

Página 92

VT100 Interface 4-65Area IDThis parameter has the same format as the IP Address of the Mask Address.Values: 0.0.0.0−255.255.255.255Default: 0.0.0.0Ena

Página 93

4-66 WANsuite 5260/5230It is possible that an area cannot be connected directly to the backbone. In this case a virtual link is used. To establish or

Página 94

VT100 Interface 4-67Figure 4.58Virtual Link Details ScreenTCP ServerThe TCP Server is a general-purpose application that maps arbitrary TCP port numbe

Página 95

4-68 WANsuite 5260/5230Figure 4.60TCP Connection Table ScreenThe TCP Connection Details screen (Figure 4.61) lists the index number, the endpoint name

Página 96

VT100 Interface 4-69NOTICE: You must Save and Restart for any changes in NAT configuration parameters to take effect. NAT Details ScreenThe NAT Detai

Página 97

4-70 WANsuite 5260/5230applications. The timers’ values minimize NAT resources. Generally, when a timer has expired, the resources used are no longer

Página 98

VT100 Interface 4-71Static TCP Trans Table ScreenThe Static TCP Trans Table screen (Figure 4.63) allows static mapping of global TCP Server ports to a

Página 99 - TCP Server Details Screen

4-72 WANsuite 5260/5230Figure 4.64Static TCP Translation Details ScreenNAT Ports ScreenThe parameters on the NAT Ports screen (Figure 4.65) define the

Página 100 - NAT Details Screen

VT100 Interface 4-73“Disable” will override an “Enable” parameter set under “Filter Non Local Address” on the NAT Details menu.TypeDefines whether thi

Página 101

About the WANsuite 5260/5230 1-5• SOS Mode• New Circuit InstallationWANsuite 5260/5230 Overview and AdvantagesVerilink’s WANsuite 5260/5230 is an inno

Página 102 - 3-72 WANsuite 5260/5230

4-74 WANsuite 5260/5230Figure 4.67NAT Port Status Screen IP AddressOriginal IP Address of the host. NAT IP AddressTranslated IP Address of the host. P

Página 103 - Figure 3.62

VT100 Interface 4-75Server AddressIP Address of the local UDP Server. Default is 0.0.0.0.The “Add New” prompt lets the user add additional addresses.

Página 104 - Figure 3.63

4-76 WANsuite 5260/5230DHCP Server Details ScreenThe DHCP Server Details screen (Figure 4.70) lets you configure the parameters described below.Figure

Página 105 - NAT Ports Screen

VT100 Interface 4-77The DHCP Server Details screen provides the following user-activated prompts: DHCP Hosts ScreenIn some cases, it may be necessary

Página 106 - Figure 3.67

4-78 WANsuite 5260/5230Figure 4.72Static Entries Screen MAC AddressMAC Address you want to associate with an IP address.IP AddressIP Address given to

Página 107 - DHCP Server Details Screen

VT100 Interface 4-79IP StartStarting IP Address of the DHCP client pool.IP EndEnding IP Address of the DHCP client pool.IP Exclude StartBeginning of “

Página 108 - DHCP Hosts Screen

4-80 WANsuite 5260/5230

Página 109 - Static Entries Screen

Front Panel LCD Interface 5-1C HAPTER5CHAPTER 5FRONT PANEL LCD INTERFACEIntroductionThis chapter describes the menus and options associated with the W

Página 110 - IP Address Status Screen

5-2 WANsuite 5260/5230The table below provides a brief description of the WANsuite 5260/5230’s LED indicators. Indicator DescriptionNETThis indicator

Página 111 - Software Upgrade

Front Panel LCD Interface 5-3The use of each input control button is defined in the following table: LCD Front Panel OperationAfter power is applied a

Página 112 - WILL NOT be installed

ii WANsuite 5260/5230Copyright Notice Copyright © 2002 Verilink Corporation. All rights reserved. No part of this publication may bereproduced, transm

Página 113 - Password

1-6 WANsuite 5260/5230• IP Gateway:• Frame Relay or PPP• 10/100Base-T Ethernet port• Static routes• Static Address Resolution Protocol (ARP)• Dynamic

Página 114 - In-band Management

5-4 WANsuite 5260/5230To enter an established password, press the SCROLL button until the desired character appears (the characters scroll 0–9, A–Z, a

Página 115 - Frame Relay Network

Front Panel LCD Interface 5-5Information ElementThe information element is a user-selectable field allowing changes to the setting. Initially, it is a

Página 116 - 3-86 WANsuite 5260/5230

5-6 WANsuite 5260/5230Figure 5.7WANsuite 5260 Alarms Menu TreeFigure 5.8WANsuite 5230 Alarms Menu TreeNetwork 1 and Network 2 (5260) or Network (5230)

Página 117 - Screen Components

Front Panel LCD Interface 5-7ESErrored Seconds − the number of seconds for which at least one bit error has occurred. A default threshold for alarm of

Página 118 - Field Types

5-8 WANsuite 5260/5230unit alarms a loss of DTR, which occurs when the Serial port detects that the DTR signal is low. Reset TimerThis field is the co

Página 119 - Menu Structure

Front Panel LCD Interface 5-9LOFCThe Loss of Frame Count (LOFC) represents the number of time a loss of frame is declared. A loss of frame is declared

Página 120 - System Screen

5-10 WANsuite 5260/5230SettingLets you specify on which channels to perform the BERT. Values: Net, Idle, Channel 1..., Channel 31 Default: NetPatternL

Página 121 - Maintenance Reset

Front Panel LCD Interface 5-11LoopLets you specify the type of loop test (if any) to be performed on the selected serial interface.Values: No Test, Po

Página 122 - Save and Restart

5-12 WANsuite 5260/5230Configuration MenuThe Configuration menu lets you configure the parameters of the various interfaces.Figure 5.11WANsuite 5260 C

Página 123 - Network Config Screens

Front Panel LCD Interface 5-13Subnet MaskThis menu lets you define the network portion of the unit’s IP address. To establish the Subnet Mask (a numbe

Página 124 - Network 2 Screen

About the WANsuite 5260/5230 1-7• Layer 3 support for visibility beyond the Network layer (up to 25 protocols)• “Top Talker” reports − lets you find o

Página 125 - VT100 Interface 4-9

5-14 WANsuite 5260/5230Figure 5.14 Network 1 or Network Configuration Menu Tree The Network 1 or Network interface can have independently selected val

Página 126 - Prompt Function

Front Panel LCD Interface 5-15Figure 5.15 Network 2 Configuration Menu Tree CodingSets the DSX port line coding.Values: HDB3, AMIDefault:HDB3CRC4 Mode

Página 127 - Performance Screens

5-16 WANsuite 5260/5230Figure 5.16Serial 1 and Serial Interface 2 (5260) or Serial (5230)Configuration Menu Tree TypeSelects the type of interface (ba

Página 128 - Serial Screens

Front Panel LCD Interface 5-17DSRData Set Ready (DSR) can be set to “True,” “False,” or “Internal.” The “Internal” option sets DSR “On” if the port is

Página 129 - VT100 Interface 4-13

5-18 WANsuite 5260/5230configuring the next four parameters (Start Channel, Number of Channels, and Bundling). The menu displays the calculated rate i

Página 130 - Assignments on page A-7

Front Panel LCD Interface 5-19LLThe Local Loopback (LL) parameter can be set to “Enable” or “Disable.” Selecting “Enable” allows the unit to go into L

Página 131 - VT100 Interface 4-15

5-20 WANsuite 5260/5230Diag MsgsEnables the Supervisory port to send out diagnostic messages upon power-up.Values: Enable, DisableDefault:EnableNOTICE

Página 132 - Ethernet (IP Details) Screen

Front Panel LCD Interface 5-21characters that define your password, press the SELECT button; the menu will then prompt you to “Verify” the password. R

Página 133 - Figure 4.13

5-22 WANsuite 5260/5230

Página 134 - Service Table Screen

Specifications A-1A PPENDIXAAPP ENDIX ASPECIFICATIONSNetwork 1 (5260) or Network (5230) InterfaceLine Rate: 2.048 Mbps (±50 bps) unframedLine Framing:

Página 135 - Service Details Screen

1-8 WANsuite 5260/5230The front panel LED status indicators are defined below: Indicator DescriptionNETThis indicator is off (not illuminated) when th

Página 136 - DS0 Monitor Details Screen

A-2 WANsuite 5260/5230Serial Interface(s)Connection: DB-25 femaleDTE Ports: Selectable RS-530, RS-232, V.35, or X.21Data Rate: Synchronous, nx64 kbp

Página 137 - DS0 Status and Alarm Table

Specifications A-3Figure A.1Line Loopback (LLB) and Maintenance Loopback (MLB) Figure A.2Port Loop and V.54 Loopback Line Loopback (LLB)Internal Logic

Página 138 - Channel Table Details Screen

A-4 WANsuite 5260/5230AlarmsActivation: Programmable thresholds on all interfacesReporting: SNMP trapsPower100−240 VAC or 7 W maximum, 24 BTU maximum1

Página 139 - Figure 4.19

Specifications A-5Tx/Rx Mgmt OctetsPeak/Average ThroughputPeak/Average Round-trip delayRound-trip delay time-outsUAS (unavailable seconds)PPP Statisti

Página 140 - Field Description

A-6 WANsuite 5260/5230Ordering InformationEach WANsuite 5260/5230 unit ships with the following standard equipment:Optional EquipmentThe following opt

Página 141 - VT100 Interface 4-25

Specifications A-7Connector Pin AssignmentsThe Serial Interface is a standard DB-25 jack.Serial Interface Pin Assignments for DTE Mode (Packet Use Onl

Página 142 - 4-26 WANsuite 5260/5230

A-8 WANsuite 5260/5230Serial Interface Pin Assignments for DCE Mode *This refers to the DB-25 Serial interface connector on the back of the unit.Ether

Página 143

Specifications A-9Network 1 (5260) and Network (5230) Interface Pin AssignmentsThe NET 1and NET physical interfaces are both standard RJ-48C, eight-pi

Página 144 - Transmit

A-10 WANsuite 5260/5230

Página 145 - PPP Service Details Screen

SNMP Agent B-1A PPENDIXBAPPENDIX BSNMP AGENTIntroductionThis chapter provides specific information for configuring and using the SNMP agent within th

Página 146 - 4-30 WANsuite 5260/5230

About the WANsuite 5260/5230 1-9The user-activated input control buttons used to access and set configuration and control options from the LCD menus a

Página 147 - PPP Statistics

B-2 WANsuite 5260/5230• rfc2863.mib − describes generic objects for network interface sub-layers (This MIB is an updated version of MIB-II's ifTa

Página 148 - PAP Table

SNMP Agent B-3loading MIBs may vary from one platform to another, the following basic steps are the same. 1 The SNMP manager has a directory for MIBs

Página 149 - PAP Details

B-4 WANsuite 5260/5230

Página 150 - SCADA Service Details Screen

Five-Year Hardware Limited WarrantyI. Limited Warranty. Subject to the limitations and disclaimers set forth in this Hardware Limited Warranty, Veril

Página 151 - IP Service Details Screen

1-10 WANsuite 5260/5230Supervisory PortThe SUPERVISORY PORT on the 5260/5230 is a DB-9 female DCE connector configured for 8 bits, no parity, and 1 st

Página 152 - Endpoint Table Screen

About the WANsuite 5260/5230 1-11Network 1 Interface (5260) and Network Interface (5230)There are two NET 1 connections on the rear panel of the WANsu

Página 153 - Endpoint Details Screen

1-12 WANsuite 5260/5230Figure 1.4WANsuite 5260/5230 Power Supply UnitWhen power is applied to the unit, the front panel indicators flash for approxima

Página 154 - 4-38 WANsuite 5260/5230

Installation 2-1C HAPTER2CHAPTER 2INSTALLATIONThis chapter describes the contents of your WANsuite 5260/5230 shipment and provides information on conn

Página 155 - DLCI Details Screen

2-2 WANsuite 5260/5230For specific applications, see Appendix A, Specifications, for additional cables and adapters. Contact Verilink Technical Suppor

Página 156

Installation 2-35 By default, the “Baud Rate” field will display 115200 (bits per second). For the purpose of this installation, do not change the dis

Página 157 - VT100 Interface 4-41

iii• This product should be operated only from the type of power source indicated on the marking labeland manual. If you are unsure of the type of pow

Página 158 - DLCI Status Table

2-4 WANsuite 5260/5230

Página 159 - DLCI Statistics Screen

Web Server Interface 3-1C HAPTER3CHAPTER 3WEB SERVER INTERFACEThe WANsuite 5260/5230 has an innovative, embedded Web-based user interface (WANsight) f

Página 160 - DLCI Table Screen

3-2 WANsuite 5260/5230To access the Web server interface, type the unit’s IP address in the browser’s Address (or Location) field and press the “Enter

Página 161 - Rule Configuration Screen

Web Server Interface 3-3Figure 3.1Unit ScreenThe Unit screen displays the following fields:The Unit screen provides the following user-activated butto

Página 162 - Rule Config Screen

3-4 WANsuite 5260/5230Maintenance ResetUse this button to access a screen where you can perform a Maintenance Reset (Figure 3.2). When you click on th

Página 163 - Figure 4.39

Web Server Interface 3-5InterfacesThe WANsuite 5260 has the following interfaces: Network 1, Network 2 (also known as an Equipment or DSX port), Seria

Página 164 - Diagnostics Screen

3-6 WANsuite 5260/5230FramingSelects the framing for the network side of the DSU/CSU. Values CCS, CAS, UnframedDefault: CCSCodingSets the network side

Página 165 - Test Details Screens

Web Server Interface 3-7The 15-minute time frame is not based on the TR 54016 or T1.403 interval boundaries, but is a time window based on the accumul

Página 166 - NOTICE: The 2

3-8 WANsuite 5260/5230RASSets the Remote Alarm Seconds (RAS) threshold. An RAS is generated by the terminal equipment when an improper signal is recei

Página 167 - Figure 4.43

Web Server Interface 3-9In addition to the error parameters found in the Error Status and Thresholds Table on the Network screens, the following error

Página 168

iv WANsuite 5260/5230

Página 169 - Top Talkers Screen

3-10 WANsuite 5260/5230Figure 3.7Performance 30 Day Screen Serial ScreensThe Serial 1 and Serial 2 screens on the WANsuite 5260 and Serial screen on t

Página 170

Web Server Interface 3-11NOTICE: V.35 requires the use of an optional cable. Refer to Optional Equipment on page A-6 for ordering information.ModeBy

Página 171 - RIP Parameters

3-12 WANsuite 5260/5230Channel RateThe unit can operate at any data rate that is a multiple of 56 or 64 kbps. If “Νx64K” is selected, the ones density

Página 172 - Circuit Table Screen

Web Server Interface 3-13V.54Selecting “Enable” allows the unit to respond to in-band V.54 loop codes. If you select “Disable,” the unit ignores these

Página 173 - Circuit Details Screen

3-14 WANsuite 5260/5230DTR Alarm Control and Status TableIn addition to the configurable fields, the Serial screens display a table that lets you set

Página 174 - 4-58 WANsuite 5260/5230

Web Server Interface 3-15Gateway IP AddressIP address of the default gateway (router) on the LAN side of the unitDHCP ClientIf DHCP Client is enabled

Página 175 - Static Route Table Screen

3-16 WANsuite 5260/5230Supervisory ScreenThe Supervisory screen (Figure 3.11) displays the current speed of the Supervisory port interface and other p

Página 176 - Dynamic Route Table Screen

Web Server Interface 3-17Current Pin StatusThe Current Pin Status, which shows the state of the RS-232 pins, is also displayed on the Supervisory inte

Página 177 - Static ARP Table Screen

3-18 WANsuite 5260/5230on screen. The Interface for the newly added service will be “Unassigned.” To assign an interface for the new service, click on

Página 178 - ARP Details Screen

Web Server Interface 3-19Interface Details ButtonClicking the “Interface Details” button on the Service Details screen lets you view interface paramet

Página 179 - Area Table Screen

vTable of ContentsPrefaceAbout this Manual ...

Página 180 - Area Details Screen

3-20 WANsuite 5260/5230what are considered high and low DS0 utilization parameters, and will report alarms if the monitored statistics rise above or f

Página 181 - Virtual Link Table Screen

Web Server Interface 3-21The user-activated buttons listed below are at the bottom of the DS0 Monitor Details screen. Figure 3.16Channel Table Details

Página 182 - Virtual Link Details Screen

3-22 WANsuite 5260/5230Idle PatternSelects the DS0 idle pattern sent by the unit and lets the unit determine if the DS0 idle pattern has been sent by

Página 183 - TCP Server Screen

Web Server Interface 3-23Figure 3.19Frame Relay Service Details Screen Interface TypeIf this service is connected to a Frame Relay network, the Interf

Página 184 - TCP Connection Table Screen

3-24 WANsuite 5260/5230N1This counter indicates the number of “keep alive” status inquiries that are sent between full status requests.Values: 5–255De

Página 185

Web Server Interface 3-25Enforce CIR and BeIf this parameter is set to “Yes,” the unit will enforce Committed Information Rate and Excess Burst accord

Página 186

3-26 WANsuite 5260/5230Round Trip Delay SizeSpecifies the frame size (in bytes) of packets making the round-trip.Round Trip Delay RateSpecifies the ra

Página 187 - Static TCP Trans Table Screen

Web Server Interface 3-27Clicking the “Frame Relay Statistics” button brings up a table (Figure 3.20) that reports on the status and condition of LMI

Página 188

3-28 WANsuite 5260/5230BECNNumber of Backward Explicit Congestion Notification frames received.InvalidsNumber of invalid frames received.Stat Inquirie

Página 189 - NAT Port Details Screen

Web Server Interface 3-29Message SizeMaximum number of characters to buffer before sending a frame.Values: 0−1024Default: 256Idle Character DelayMaxim

Página 190 - Static UDP Trans Table Screen

vi WANsuite 5260/5230Chapter 3 Web Server InterfaceWeb Server Access ...

Página 191 - Figure 4.69

3-30 WANsuite 5260/5230Figure 3.23SCADA Device Details ScreenPPP Service Details ScreenClick on “PPP” under the “Type” column on the Services screen t

Página 192

Web Server Interface 3-31MRUThe Maximum Receive Units configuration option may be set to inform the peer that the implementation can receive larger pa

Página 193

3-32 WANsuite 5260/5230Initiate NegotiationDetermines whether the port actively negotiates with the peer site or passively waits for negotiation reque

Página 194

Web Server Interface 3-33Figure 3.25PPP Statistics ScreenTransmitFramesNumber of frames transmitted by the port.OctetsNumber of octets transmitted by

Página 195

3-34 WANsuite 5260/5230The PPP Statistics screen provides the following user-activated buttons: PAP TableAt the bottom of the PPP Services Details scr

Página 196 - 4-80 WANsuite 5260/5230

Web Server Interface 3-35Figure 3.27PAP Details Screen To change the Username and Password for a selected PAP Index (PAP: 1 in the example above), ent

Página 197 - Description of Front Panel

3-36 WANsuite 5260/5230Figure 3.29CHAP Details Screen To change the Username and Secret for a selected CHAP Index, enter the new information in the ap

Página 198 - The indicator lights

Web Server Interface 3-37NOTICE: Endpoint names of the form PPP-Sn are reserved by the system. These system-generated endpoints cannot be modified.Fi

Página 199 - LCD Front Panel Operation

3-38 WANsuite 5260/5230likely should) be changed to reflect a remote location name. Submitting a changed Name parameter will cause the endpoint entry

Página 200 - Interface Conventions

Web Server Interface 3-39WANsuite 5260/5230 unit here. This DLCI can be used for management only, or for management and actual data. If this parameter

Página 201 - Alarms Menu

viiTrusted Neighbors Screen ... 3-64Area Table Screen

Página 202 - Status Menu

3-40 WANsuite 5260/5230Figure 3.32DLCI Details Screen The unit uses the first three configuration parameters (Protocol Encapsulation, Proprietary Traf

Página 203 - DTR Alarm

Web Server Interface 3-41Be (bps)If an Excess Burst Rate is configured here, its value will be used instead of the default excess burst of the Frame R

Página 204 - (read-only fields)

3-42 WANsuite 5260/5230Remote UnitIf the remote unit is a Verilink FSx product, and FrameStart Auto Discovery is enabled, this field displays the firs

Página 205 - Maintenance Menu

Web Server Interface 3-43BECN in CIRReports if Backward Explicit Congestion Notification (BECN) has been received within CIR.UAS ThresholdSets the Una

Página 206 - Serial Maintenance Menu

3-44 WANsuite 5260/5230completed at 01:15 PM; subsequent intervals would be completed at xx:30, xx:45, xx:00 and xx:15. Interval 1 is always the lates

Página 207

Web Server Interface 3-45shows the Tx Alarm Threshold and the current Tx Alarm status (if enabled) for each rule.It is also possible to filter PPP ser

Página 208 - IP Address

3-46 WANsuite 5260/5230Figure 3.36Rule Config Screen The paragraphs below describe the rule configuration parameters and their options.ServiceSelects

Página 209 - DHCP Client

Web Server Interface 3-47IP PortEstablishes the IP port by which the rule will filter IP traffic (if enabled).Filter By IP PortEnables or disables fil

Página 210 - Figure 5.14

3-48 WANsuite 5260/5230The Period Index field is used to define the period of time for which the Traffic Meter statistics will be reported. It represe

Página 211 - • Thru − Allocated to NET 2

Web Server Interface 3-49Trap IP AddressAccepts the IP address of a network device where alarm reporting traps are to be sent. Diagnostics ScreenThe D

Página 212 - Figure 5.16

viii WANsuite 5260/5230Endpoint Table Screen ...

Página 213

3-50 WANsuite 5260/5230ESDisplays the number of asynchronous errored seconds detected since the BERT began or since error statistics were last cleared

Página 214 - 5-18 WANsuite 5260/5230

Web Server Interface 3-51BERT PatternSpecifies the pattern to be transmitted during a test for the selected port. Values: Marks, QRSS, 511, 2047, 215,

Página 215 - Figure 5.17

3-52 WANsuite 5260/5230Figure 3.41Serial Interface Test Details ScreenBERT Table on Serial Interface Test Details ScreenThe BERT table lets you set th

Página 216 - Utilities Menu

Web Server Interface 3-53Errored SecondsDisplays the number of asynchronous errored seconds that have been detected since the test began or since erro

Página 217 - Log Out Menu

3-54 WANsuite 5260/5230Figure 3.42Trap Log Screen Top Talkers (Top N Details Screen)Clicking on the Top Talkers link in the navigation tree displays t

Página 218 - 5-22 WANsuite 5260/5230

Web Server Interface 3-55the outlined box at the bottom of the screen. This report comprises elements as defined in the following paragraphs.Requested

Página 219 - PECIFICATIONS

3-56 WANsuite 5260/5230Figure 3.44IP Gateway Screen RIP ParametersRIP EnableGlobally enables RIP 1, RIP 2, or No RIP.Values: Disable, Enable RIP1, Ena

Página 220 - Diagnostics

Web Server Interface 3-57The IP Gateway screen provides the following user-activated buttons: Circuits ScreenAccess this menu by clicking on the “Circ

Página 221 - Figure A.2

3-58 WANsuite 5260/5230Figure 3.46Circuit Details Screen EndpointEndpoint name. By default, the first circuit is always the LAN circuit. All

Página 222 - Environmental

Web Server Interface 3-59OSPF AreaRepresents the area that this circuit is part of.OSPF LSA TimerDetermines how often the Link State Acknowledgment (L

Página 223 - Standards

ixSerial Maintenance Menu ... 5-10Configuration Menu

Página 224 - Optional Equipment

3-60 WANsuite 5260/5230Static Routes ScreenUnder some circumstances, it may not be necessary for a router to learn a route using ordinary means such a

Página 225 - Connector Pin Assignments

Web Server Interface 3-61Figure 3.48Route Details Screen EndpointEndpoint name (or interface) through which to send the IP packet to reach the

Página 226 - Pin Ethernet Interface

3-62 WANsuite 5260/5230Dynamic Route Table ScreenAccess this menu by selecting “Static Route Table” from the RIP Parameters table on the IP Gateway me

Página 227 - Assignments

Web Server Interface 3-63Figure 3.50ARP Table Screen EndpointEndpoint name (or Interface) through which to send the IP packet to reach the defined IP

Página 228 - A-10 WANsuite 5260/5230

3-64 WANsuite 5260/5230IP AddressIP address of the circuit.Values: 0.0.0.0−255.255.255.255Default: 0.0.0.0MAC AddressMAC address of the Host to be rea

Página 229 - SNMP MIBs

Web Server Interface 3-65The Trusted Neighbors screen provides the following user-activated buttons: Area Table ScreenAn Area allows growth and makes

Página 230 - SNMP Trap Configuration

3-66 WANsuite 5260/5230Area Details ScreenAccess this screen by clicking on the Area Details button on the Area Table screen.Figure 3.54Area Details S

Página 231 - SNMP Agent B-3

Web Server Interface 3-67falling within the configured range are described by a single LSA, thus decreasing the size of the LSA database.Values: 0.0.0

Página 232 - B-4 WANsuite 5260/5230

3-68 WANsuite 5260/5230Access this screen by selecting the Virtual Link Table from the OSPF Parameters table on the IP Gateway screen.Figure 3.55Virtu

Página 233

Web Server Interface 3-69The Virtual Link Details screen provides the following user-activated buttons: TCP ServerThe TCP Server is a general-purpose