— CONFIGURATION NOTES —
TAPS units must
be configured in pairs. In each
pair, one unit must be configured as a MASTER
and one as a SLAVE.
Each pair of TAPS units must
be configured for
the same mode, NORMAL or TRANSPARENT
A pair of TAPS units configured as NORMAL
may not
be placed in the same circuit with a pair
configured as TRANSPARENT.
It is allowed (as the diagram shows) to have two
pairs of TAPS units on the same circuit if they are
configured for NORMAL mode.
Take note of the setting for switches S2-7 and S2-
8. These switches determine the CONFIGURA-
TION SOURCE for the 1557 card. Switch
options for Configuration Source are shown on
the front page of this document. The four choices
are explained in the 1557 Users Manual.
A 1559 APS Manager connected to a 1557 con-
figured as a MASTER unit can monitor and do
maintenance functions on both the master unit
and its corresponding slave unit.
A 1559 APS Manager connected to a 1557 con-
figured as a SLAVE unit can monitor only the
performance data for the slave unit. No mainte-
nance functions are available through the slave
unit.
Normal Slave
Transparent Slave Transparent Master
Normal Master
CO #1 CO #2
CO #2CO #1
1
5
5
7
1
5
5
7
1
5
5
8
CPE CPE
A
B
IOC
EQUIPMENT EQUIPMENT
ACCESS
S2-5 closed
12345678
OPEN
S3-6 open
12345678
OPEN
S2-5 closed
12345678
OPEN
S3-6 closed
12345678
OPEN
S2-5 open
12345678
OPEN
S3-6 open
12345678
OPEN
S2-5 open
12345678
OPEN
S3-6 closed
12345678
OPEN
CPE
ACCESS
A
B
EQUIPMENT EQUIPMENT
ACCESS
CPE
IOC
B
A
1
5
5
7
1
5
5
7