Configuration Screens 65
Remote Alarm Seconds
Generated by the terminal equipment when an improper signal is received from the
facility (or after receiving unframed all ones).
AIS Seconds
A one-second period in which all ones are received.
Out of Frame Seconds
A one-second period in which a frame sync loss occurred.
BPV Seconds
A one-second period in which at least one bipolar violation occurred.
Alarm Reset Timer
Determines the number of seconds after alarm conditions clear before indications
are removed.