81
Note: Only circuits serviced by the unit are listed.
The RS-232 interface is only recommended for data rates of 128 kHz and below.
The connector is a standard female DB-25.
All unbalanced bipolar inputs and outputs meet the physical and electrical specifications of
ITU V.28.
Table A-5 RS-232 Interface Specifications
Characteristics Specifications
Line Drivers
Output Voltage ±10 Volts maximum
Mark Voltage (Off) <5 V (±0.5 V) into 3000
Space Voltage (On) >+5 V (±0.5 V) into 3000
Output Impedance 300 minimum
Short Circuit Current 12 mA maximum
Line Receivers
Input Voltage ±25 V maximum
Load Impedance 3000 minimum
Mark Voltage (Off) 25 to 0 VDC
Space Voltage (On) +2 to +25 VDC
Table A-6 RS-449/422 Interface Specifications
Characteristics Specifications
RS-449/422 Drivers
Source Impedance <100
Differential Output Voltage between 2 to 6 VDC offset at 2.5V (< +0.5V
and >0.5 V) optional for MIL-STD-114
Short Circuit Current <150 mA
Output Rise Time <20 nanoseconds
RS-449/422 Receivers
Impedance 100 terminated
Differential Input Voltage >+0.5 V or <0.5 V
Data
Data Mark (binary 1 or OFF state) A terminal more negative than the B terminal
Data Space (binary 0 or ON state) A terminal more positive than the B terminal