Access System 2000
Red Zone Encryption Management System (REMS)
Release Notes
6
Red Zone Encryption Management System (REMS) Release Notes Part Number 883-101598-001-A
BRC Timing Options
Select one of the settings 40 through 43, which are canned programs.
Then select from 50 through 63 as appropriate.
40 (Canned program) Internal timing, generate
PRMs (Performance Report Messages)
41 (Canned program) Network loop timing,
generate PRMs
42 (Canned program) Internal timing, no PRMs
43 (Canned program) Network loop timing, no
PRMs
50 Internal timing
51 Network loop timing
52 Equipment timing
53 External timing RS442
54 External timing TTL
62 Disable transmit of BRC message
63 Enable transmit of BRC message
Correct the error in Troubleshooting chapte
On page 8-5 of the rev A(1), Red Zone Encryption Management System
User Manual, delete step 5, b of the eight-step procedure at the top of the
page. Step 5, b does not apply.
Correct spelling of T-Berd and FireBerd
On page 8-4, in the first paragraph under the Section, “Troubleshooting
using a testset and loopback,” the correct spelling of the example testsets
should be: “...FIREBERD, T-BERD, or Verilink’s TS2000.”