12 C
HAPTER
2: I
NSTALLATION
AND
C
ONFIGURATION
Supplied
Materials
The T Lite is shipped from the factory with the following
standard equipment.
✦ external AC power supply
✦ reference manual
✦ adhesive strip
✦ two 9-foot RJ48-to-RJ48 cables (part number 9-1544-619-009)
Wallmount
Installation
Using Adhesive Strips
1 Select a place close to an 115 VAC outlet with clearance for the
signal and power cables as well as for bantam test cables. The
indicators and switches should be easily accessible.
2 Verify the mounting surface is clean.
3 Cut the adhesive strip to the desired length and affix the backing
of one piece to the underside of the unit.
4 Attach the other adhesive strip to the piece on the underside of
the unit.
5 Remove the backing to expose the sticky surface.
6 Press the underside of the unit firmly against the selected place.
Using Screws
1 Select a place close to an 115 VAC outlet with clearance for the
signal and power cables as well as for bantam test cables. The
indicators and switches should be easily accessible.
2 Vertically place two #6 screws 3-13⁄32 inches apart at the
selected place. Leave the screws out about an eighth of an inch.
3 Place the upright unit over the screws until the holes engage and
slide the unit down until it locks.
Connections
The T Lite has RJ-48C connectors for the network and
equipment interfaces and a terminal strip for the power
connection. The following paragraphs describe these connections.
Equipment and
Network
Connections
Table 2-1 shows the pinout for the network and equipment
connectors. The interface for these connectors is an RJ-48C jack.
Table 2-1 Equipment and Network Connector Pinout
Pin NET Equipment
1 R1 (ring, receive from network) R1 (ring, transmit to equipment)
2 T1 (tip, receive from network) T1 (tip, transmit to equipment)
4 R (ring, transmit to network) R (ring, receive from network)
5 T (tip, transmit to network) T (tip, receive from network)
3, 6–8 not used not used