Verilink WANsuite 7205 (34-00317.B) Product Manual Manual do Utilizador Página 201

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 221
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 200
VT100 Interface 4-79
Figure 4.75
HDLC Monitor Details Screen
Service Attached
Service to which an HDLC detector is assigned and for which statistics are
collected.
Values: Service Index, Disabled
Default: Disabled
NOTICE: A Serial 1 service can only be attached to Detector 1, and a Serial 2
service can only be attached to Detector 2.
Service (bps)
Bit rate of the service for which statistics are being collected.
Alarm Reset Timer
(sec)
Number of seconds a utilization alarm condition must not be present before
the unit resets the alarm. Zero (0) indicates the timer is disabled.
Values: 0900
Default: 30
Rx High Utilization
(%)
What the user considers Rx high utilization (expressed as a percentage) for
this service.
Values: 1100
Default: 75
Rx High Threshold
(sec)
Number of seconds Rx high utilization must be present before an alarm
reports.
Values: 0900
Default: 0 (Rx High Utilization Alarm Disabled)
Rx End of Day Low
Utilization %
What the user considers Rx low utilization at the end of the day for this
service.
Values: 0100
Default: 0 (Rx Low Utilization Alarm Disabled)
Vista de página 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 220 221

Comentários a estes Manuais

Sem comentários