364 CHAPTER 21: SIMPLE IP/IPX ROUTER CONFIGURATION SCENARIO USING NMCS SCREENS AND PROPRIETARY
Figure 21-12
Type Y in the Circuit Configuration Menu and Press F10
TXPORT INTELLINET Configuration Program
Configuration
IPX ROUTER parameters
Line Module [ ]
Copy Parameters from Configuration [ ] Module [ ]
Enable IPX Router [Y] Enable SAP [Y]
Enable RIP [Y] Enable NLSP [N]
Enable IPXWAN2 [N] IPX Maximum Hop Count [ 16]
Circuit Configuration menu [ ] Other parameters menu [ ]
NLSP Parameters
Router Id [ ] Internal Network Number [ ]
Router Name [TXPORT Router 001 ]
NLSP Area Network Number [ 0] NLSP Area Mask [ 0]
Broadcast HELLO Interval [ 10] Non Broadcast HELLO Int. [ 10]
Designated Router HELLO Int[ 3] Holding Time Multiplier [ 5]
CLear IPX ROUTER application [ ]
Figure 21-13
Enter at Circuit by Pressing F3
TXPORT INTELLINET Configuration Program
Configuration
IPX Circuit parameters
Line Module [ ]
Copy Parameters from Configuration [ ] Module [ ]