Verilink C100 (880-502893-001) Product Manual Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware de computador Verilink C100 (880-502893-001) Product Manual. Verilink C100 (880-502893-001) Product Manual User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 135
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - User Manual

Part Number 880-502893-001-BJune 1999“C” Series• C100 T1/FT1 CSU/DSU• C150 T1/FT1 CSU/DSU with Drop and InsertUser Manual

Página 2 - Copyright notices

Contentsx C100 and C150 T1/FT1 CSU/DSUs6/15/99Figure B-1 Example: C100/C150 T1 CSU/DSUs connecting two LANs together over T1/F-T1 ...B-2Figure

Página 3 - Warnings and Caution Notices

Sample ApplicationsB-6 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99C100/C150 T-1 CSU/DSU Connecting Two Routers in LDM modeThe T-1 CSU/DSU’s can be us

Página 4 - Instructions

Sample Applications6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUB-7Table B-3 Switches: C100/150 T-1 CSU/DSUs Connecting Two Routers in LDM Mode OFF S

Página 5 - Table of Contents

Sample ApplicationsB-8 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99C150 T-1 CSU/DSU connecting two PBXs and converting D4 To ESFThe T-1 CSU/DSU can be

Página 6

Sample Applications6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUB-9Table B-4 Switches: C150 CSU/DSUs connecting PBXs over T-1 and converting D4 to ESF

Página 7 - C100 and C150 T1/FT1 CSU/DSUs

Sample ApplicationsB-10 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99C150 T-1 CSU/DSU connecting two PBXs and two routersFigure B-5 shows a typical app

Página 8

Sample Applications6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUB-11Table B-5 Switches: C150 CSU/DSUs connecting PBXs and routers over a T-1 facility

Página 9 - List of Figures

Sample ApplicationsB-12 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99

Página 10 - Contents

6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUC-1AppendixCInterfaces and CablesThis appendix contains technical information on interfaces and cables.Net

Página 11 - List of Tables

Interfaces and CablesC-2 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99CCITT V.35 Channel InterfaceThe Winchester 34 pin female connector on the rear of

Página 12

Interfaces and Cables6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUC-3RS232/RS530/RS422 channel interfacesThe DB25 pin female on the rear of the unit ma

Página 13 - Introduction

List of Tables6/15/99C100 and C150 T1/FT1 CSU/DSUs xiTable 3-1 C100/C150 Switch pack 1—Unit Configuration ...

Página 14

Interfaces and CablesC-4 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Table C-4 DB25-Pin Female Connector Wiring on Rear of Unit When RS530 Is Selected

Página 15 - C100 front and rear

Interfaces and Cables6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUC-5Console IN InterfaceThe Console IN Interface is a 6-position modular connector. Th

Página 16 - C150 front and rear

Interfaces and CablesC-6 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99CablesTwo cables and an RS232 hood come standard with the T-1 CSU/DSU: Part Numb

Página 17 - C150 rear panel

Interfaces and Cables6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUC-7Part Number 458-503010-001This cable is an RJ-11C 6-pin modular to modular 6-foot

Página 18 - Applications

Interfaces and CablesC-8 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Part Number 458-502361-015Optional DB25 (RS530) to DB37 (RS422) adapter 6-foo

Página 19 - C150 only

6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-1AppendixDC100 and C150 SNMP MIBThis appendix contains technical specifications for the C100 and C150 S

Página 20

C100 and C150 SNMP MIBD-2 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99Transmission groupThe C150 and C100 support the DS1/E1 MIB (RFC1406) in the tra

Página 21

C100 and C150 SNMP MIB6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-3DS1 Near End GroupThe DS1 Near End Group consists of four tables: DS1 Configurat

Página 22

C100 and C150 SNMP MIBD-4 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99dsx1LineType Object (dsx1ConfigEntry 5)This read-write variable indicates the v

Página 23 - Installation

C100 and C150 SNMP MIB6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-5sending a loopback termination requestdsx1SendOtherTestPatternsending a test pat

Página 24

Contentsxii C100 and C150 T1/FT1 CSU/DSUs6/15/99

Página 25 - Overview

C100 and C150 SNMP MIBD-6 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/991. The dsx1LineStatus is a bit map represented as a sum; therefore, it can repr

Página 26 - IMPORTANT

C100 and C150 SNMP MIB6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-7dsx1Fdl Object (dsx1ConfigEntry 13)This bitmap describes the use of the faciliti

Página 27 - Switches, console

C100 and C150 SNMP MIBD-8 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99dsx1CurrentCSSs Object - (dsx1CurrentEntry 6)The number of Controlled Slip Seco

Página 28 - Remote loop

C100 and C150 SNMP MIB6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-9dsx1IntervalNumber Object - (dsx1IntervalEntry 2)A number between 1 and 96, wher

Página 29 - NI Coding

C100 and C150 SNMP MIBD-10 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99dsx1IntervalBESs Object - (dsx1IntervalEntry 10)The number of Bursty Errored S

Página 30 - Line build out

C100 and C150 SNMP MIB6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-11dsx1TotalUASs Object - (dsx1TotalEntry 5)The number of Unavailable Seconds enco

Página 31 - Channel or DSX-1 timing

C100 and C150 SNMP MIBD-12 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99The DS1 fractional table identifies which DS1 channels associated with a CSU a

Página 32 - DSX1 framing

C100 and C150 SNMP MIB6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-13dsx1FracIndex Object - (dsx1FracEntry 1)The index value which uniquely identifi

Página 33 - Idle or busy

C100 and C150 SNMP MIBD-14 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99Private Enterprise - Verilink Proprietary CSU-1-MIBThe Verilink CSU-1-MIB is a

Página 34 - Synchronous

C100 and C150 SNMP MIB6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-15The following notes apply: 1. For the purpose of this appendix, all information

Página 35 - 56000 or 64000

Chapter6/15/99Verilink C100 and C150 T1/FT1 CSU/DSU1-11IntroductionThis manual is the operating and reference manual for the Verilink “C” Series produ

Página 36 - Signal Detect)

C100 and C150 SNMP MIBD-16 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99sysTiming Object (sysConfigEntry 4)This variable defines the system timing opt

Página 37 - Remote T-1 CSU/DSU

C100 and C150 SNMP MIB6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-17chnData Object (chnConfigEntry 3)This variable determines whether data to and f

Página 38

C100 and C150 SNMP MIBD-18 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99dsx1LineLength (y = 6)dsx1TrunkProcessing (y = 7)dsx1Enable Object (dsx1Config

Página 39 - DS-O assignment

C100 and C150 SNMP MIB6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsD-19The following notes apply: The dsx1LineStatus is a bit map represented as a sum

Página 40

C100 and C150 SNMP MIBD-20 Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99

Página 41

VERILINK CORPORATION145 BAYTECH DRIVESAN JOSE, CALIFORNIA 95134TEL: (408) 945-1199FAX: (408) 262-6260880-502893-001-B June 1999Buildin

Página 42 - Channel LED Indicators

Introduction1-2Verilink C100 and C150 T1/FT1 CSU/DSU06/12/97Standards complianceThe C100/C150 is compliant with the following telecommunication and Fe

Página 43 - CI Chan DTR

Introduction06/17/97C100 and C150 T1/FT1 CSU/DSU1-3Controls, indicators, user interfaces, and portsThis sections describes the C100/150 user interface

Página 44

Introduction1-4Verilink C100 and C150 T1/FT1 CSU/DSU06/12/97C100 rear panel The C100 has no DSX-1 connector on its rear panel.Figure 1-2 C100 rear pan

Página 45 - Loopback

Introduction06/17/97C100 and C150 T1/FT1 CSU/DSU1-5C150 rear panelThe C150 has a DSX-1 connector on the rear panel.Figure 1-4 C150 rear panel

Página 46 - Local DSX1 channel

Introduction1-6Verilink C100 and C150 T1/FT1 CSU/DSU06/12/97ApplicationsThe C150 T-1 CSU/DSU can be used in all C100 applications plus drop-and-insert

Página 47 - Channel Loopback

Introduction06/17/97C100 and C150 T1/FT1 CSU/DSU1-7Figure 1-7 shows a typical application for the CSU/DSU connecting two sites and using both channels

Página 48 - Remote Network

Copyright noticesVERILINK CORPORATION DISTRIBUTES THIS REFERENCE “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER LIMITED OR IMPLIED. Verilink Corporation

Página 49 - Remote DSX1

Introduction1-8Verilink C100 and C150 T1/FT1 CSU/DSU06/12/97Figure 1-9 shows a typical application for the C150 CSU/DSU connecting two sites and using

Página 50 - Test Pattern

Introduction06/17/97C100 and C150 T1/FT1 CSU/DSU1-9Figure 1-11 shows a typical application for the CSU/DSU connecting two sites over a T-1 facility. I

Página 51 - C150 Test Pattern

Introduction1-10Verilink C100 and C150 T1/FT1 CSU/DSU06/12/97

Página 52 - Push-button

Chapter6/15/99Verilink C100 and C150 T1/FT1 CSU/DSU2-12 InstallationUnpacking and InspectionAll C100/C150 T-1 CSU/DSU&ap

Página 53 - C100 and C150 T1/FT1 CSU/DSU

Installation2-2Verilink C100 and C150 T1/FT1 CSU/DSU06/12/97When installing a system with a DSX1 channel, keep it disabled through the initial install

Página 54 - 500 Ohms

Chapter6/15/99Verilink C100 and C150 T1/FT1 CSU/DSU3-13 Configuration Using the DIP SwitchesThis chapter describes confi

Página 55 - Using the Console Port

Configuration Using the DIP Switches3-2Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99After setting the DIP switches, power-on/off the unit to get it to

Página 56 - Cabling a Modem to

Configuration Using the DIP Switches06/17/97C100 and C150 T1/FT1 CSU/DSU3-3Programming the unit configuration (C100 and C150)Switch pack 1 is used to

Página 57 - Using the console port

Configuration Using the DIP Switches3-4Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99When position 6 is set to On and 7 off, only the console port caper

Página 58 - Console

Configuration Using the DIP Switches06/17/97C100 and C150 T1/FT1 CSU/DSU3-5Programming the network interfaceSwitch pack 2 is used to program the Netwo

Página 59 - Activating and

Warnings and Caution NoticesNote: In ACE-based modules, the battery referred to in the following notices is contained inside the clock chip.EnglishDAN

Página 60 - Navigating the

Configuration Using the DIP Switches3-6Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99DensitySwitch pack 2 position 3 determines whether the unit will en

Página 61 - Utilities

Configuration Using the DIP Switches06/17/97C100 and C150 T1/FT1 CSU/DSU3-7Another common timing option is Internal. Many T-1 facilities provided to t

Página 62 - Set Password

Configuration Using the DIP Switches3-8Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Programming the DSX1 Interface (C150 only)Switch pack 3 is used to

Página 63 - Console Port

Configuration Using the DIP Switches06/17/97C100 and C150 T1/FT1 CSU/DSU3-9DSX1 codingSwitch 3 position 3 selects the type of coding the unit will gen

Página 64 - Configuration menu

Configuration Using the DIP Switches3-10Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Programming the Synchronous Channel Interface (C100 and C150)Switc

Página 65

Configuration Using the DIP Switches06/17/97C100 and C150 T1/FT1 CSU/DSU3-1156000 or 64000Switch pack 4 position 4 determines whether the bandwidth of

Página 66 - AT&T or ANSI

Configuration Using the DIP Switches3-12Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Continuous or switched carrier (Receive Line Signal Detect) contro

Página 67

Configuration Using the DIP Switches06/17/97C100 and C150 T1/FT1 CSU/DSU3-13Figure 3-1 is a block diagram which shows the end-to-end interaction of Re

Página 68 - DSX-1 line length/build out

Configuration Using the DIP Switches3-14Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99must be frequency-locked to the Receive Clock provided by the C100

Página 69 - C100/C150

Configuration Using the DIP Switches06/17/97C100 and C150 T1/FT1 CSU/DSU3-15Programming the DS-0s and DSX-1s (C100 and C150)Switch packs 5, 6, and 7 s

Página 70

Important Safety InstructionsWhen handling this equipment, follow these basic safety precautions to reduce the risk of electric shock and injury: • Fo

Página 71 - C100 DSO

Configuration Using the DIP Switches3-16Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Table 3-7 Switch pack-6: C100/C150 DS0-09 through DS0-16 and C150

Página 72

Chapter6/15/99Verilink C100 and C150 T1/FT1 CSU/DSU4-14 LED Indicators and DiagnosticsOverviewThe T-1 CSU/DSU is equippe

Página 73

LED Indicators and Diagnostics4-2Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Channel LED IndicatorsOn the C150, the first three Customer Interface LED

Página 74 - Configuring for SNMP

LED Indicators and Diagnostics6/15/99C100 and C150 T1/FT1 CSU/DSU4-3CI Chan DSRThe CI Channel DSR (Data Set Ready) LED is lit whenever CI Channel DSR

Página 75 - Management

LED Indicators and Diagnostics4-4Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Alarm and Network Interface LEDsBPV AlarmThe BPV (Bi-Polar Violation) ALA

Página 76 - 4. Power-on the unit

LED Indicators and Diagnostics6/15/99C100 and C150 T1/FT1 CSU/DSU4-5Loopbacks and diagnostics LEDsLoopbacks are labeled Local and Remote on the C100.

Página 77

LED Indicators and Diagnostics4-6Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99C150 examplesFigure 4-4 C150 T-1 CSU/DSU in Local NI Loopback Figure 4-

Página 78

LED Indicators and Diagnostics6/15/99C100 and C150 T1/FT1 CSU/DSU4-7Figure 4-6 C150 DSX-1 CSU/DSU in Local Channel Loopback Local Synchronous Channe

Página 79 - 06/17/97

LED Indicators and Diagnostics4-8Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Local Payload LoopbackC100 and C150The C150 Local Payload LOOPBACK LED is

Página 80

LED Indicators and Diagnostics6/15/99C100 and C150 T1/FT1 CSU/DSU4-9must be taken to ensure that a LOOP DOWN command is sent (pushing the Start push-b

Página 81 - Diagnostics and Statistics

Table of Contents6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUs vCHAPTER 1 - Introduction ...

Página 82

LED Indicators and Diagnostics4-10Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Remote Synchronous Channel LoopbackThe Remote Synchronous Channel LOOPBA

Página 83 - Test pattern (C150)

LED Indicators and Diagnostics6/15/99C100 and C150 T1/FT1 CSU/DSU4-11Figure 4-16 Local C100 sending pattern to network with remote T-1 CSU in NI loopb

Página 84 - Error Free Secs

LED Indicators and Diagnostics4-12Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Figure 4-19 Local T-1 C150 CSU/DSU Sending 2047 Pattern to Channel in Lo

Página 85 - Statistics

LED Indicators and Diagnostics6/15/99C100 and C150 T1/FT1 CSU/DSU4-13LED should blink at a fast rate. This means a V.54 loop On command has been sent

Página 86

LED Indicators and Diagnostics4-14Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Customer Interface DSX1 monitor jackThe CI DSX1 Monitor Jack located on

Página 87

Chapter6/15/99Verilink C100 and C150 T1/FT1 CSU/DSU5-15 Using the Console PortThe console port is the menu-driven ASCII

Página 88 - Chan CD LED

Using the Console Port5-2Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99the second unit is not used and can be stored in the shipping carton. Connect add

Página 89 - C100 and C150 Specifications

Using the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU5-3Using the console portThe console is also easy to use because the screen hierarchy is ver

Página 90 - Indicators

Using the Console Port5-4Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Console menu/command keysThe console is user-friendly and very simple to operate

Página 91 - Switches

Using the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU5-5Main MenuThe Main Menu is the first screen displayed (see Figure 5-2).Figure 5-2 Main Men

Página 92 - Power supply AC-to-DC adapter

Contentsvi Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99Synchronous Channel Internal Or External Transmit Clock ... 3-

Página 93 - Environmental

Using the Console Port5-6Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Navigating the menu treeTo display any of the five screens listed in the Main Men

Página 94

Using the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU5-7UtilitiesThe Utilities menu provides menus and commands to set the time and date, rename

Página 95

Using the Console Port5-8Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Set DatePressing the ENTER key when on Set Date selection moves the blinking curs

Página 96

Chapter6/15/99Verilink C100 and C150 T1/FT1 CSU/DSU6-16 Configuring the C100/C150 Using the Console PortThis chapter des

Página 97

Configuring the C100/C150 Using the Console Port6-2Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Configuration menuThe following illustration is a displ

Página 98 - T1 CSU/DSU

Configuring the C100/C150 Using the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU6-3The Unit Address displays the settings of the Unit Address prog

Página 99

Configuring the C100/C150 Using the Console Port6-4Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Programming the Network InterfaceNI framingThis selecti

Página 100

Configuring the C100/C150 Using the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU6-5Line build outThis selection programs the Line Build Out. In mo

Página 101 - Sample Applications

Configuring the C100/C150 Using the Console Port6-6Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Programming the customer interfaceC150DSX-1 IN OR OUTTh

Página 102 - Network provides timing

Configuring the C100/C150 Using the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU6-7Idle or busy fill characterThis field selects the fill characte

Página 103

Contents6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUsviiCHAPTER 6 - Configuring the C100/C150 Using the Console Port ...

Página 104

Configuring the C100/C150 Using the Console Port6-8Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Synchronous channel invert dataThis selection determine

Página 105

Configuring the C100/C150 Using the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU6-9Programming the DS0s (C100 and C150)C150 DSO assignmentThese fi

Página 106

Configuring the C100/C150 Using the Console Port6-10Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99

Página 107 - Interfaces and Cables

Chapter6/15/99Verilink C100 and C150 T1/FT1 CSU/DSU7-17 Configuring the Console Port for SNMPThis chapter describes usin

Página 108 - Channel Interface

Configuring the Console Port for SNMP7-2Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Configuring for SNMPThis section describes configuring the Console

Página 109 - 22 channel

Configuring the Console Port for SNMP06/17/97C100 and C150 T1/FT1 CSU/DSU7-33. Enter password and activate the console.Entering the IP address field1.

Página 110

Configuring the Console Port for SNMP7-4Verilink C100 and C150 T1/FT1 CSU/DSU6/15/993. Remove VT100 console from the CONSOLE IN connector.4. Power-on

Página 111 - Console OUT

Chapter6/15/99Verilink C100 and C150 T1/FT1 CSU/DSU8-18 Performance Monitoring with the Console PortThis chapter describ

Página 112

Performance Monitoring with the Console Port8-2Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Figure 8-2 Main Menu with Console Activated 29 APR 1997

Página 113 - 458-503012-001

Performance Monitoring with the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU8-3Local RegistersFigure 8-3 Local Registers Page 1 The Local Regist

Página 114 - 458-502361-015

Contentsviii Verilink C100 and C150 T1/FT1 CSU/DSUs6/15/99Loopbacks responded to ...

Página 115 - C100 and C150 SNMP MIB

Performance Monitoring with the Console Port8-4Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99UAS Unavailable Seconds—The number of Unavailable Seconds t

Página 116 - Transmission group

Performance Monitoring with the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU8-5Diagnostics and StatisticsFigure 8-5 Diagnostics and Statistics Scr

Página 117 - Table (x = 6)

Performance Monitoring with the Console Port8-6Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Local NI loopPressing the ENTER key while on the Local NI L

Página 118

Performance Monitoring with the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU8-7the field displays Off. Since this loopback latches the unit at the

Página 119

Performance Monitoring with the Console Port8-8Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Test SecondsWhen the Test Pattern is On, Test Seconds begin

Página 120

Performance Monitoring with the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU8-9The Network Interface (TelCo) counters can be reset only by removin

Página 121 - DS1 Current Table

Performance Monitoring with the Console Port8-10Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Loss of FrameDisplays the number of Loss Of Frames. A Loss

Página 122 - DS1 Interval Table

Performance Monitoring with the Console Port06/17/97C100 and C150 T1/FT1 CSU/DSU8-11NI Blu Alarm SecDisplays the number of seconds which had at least

Página 123

Performance Monitoring with the Console Port8-12Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Chan TX and RX LEDsThe two asterisks next to TX and RX rep

Página 124 - DS1 Total Table

6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUA-1AppendixAC100 and C150 SpecificationsThis appendix contains technical specifications for the C100 and C

Página 125 - Group (x = 13)

List of Figures6/15/99C100 and C150 T1/FT1 CSU/DSUs ixFigure 1-1 C100 front panel ...

Página 126

C100 and C150 SpecificationsA-2 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Interfaces—Electrical (DSX-1 Channel)(C150 only) Bipolar AMI/B8ZSMechanica

Página 127

C100 and C150 Specifications6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUA-3BPV ALARM Lit when Bipolar Violation received from Network.DENSITY ALARM Li

Página 128 - 1.3.6.1.4.1.2270.w.x.y.z

C100 and C150 SpecificationsA-4 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99Loopbacks generatedLocal Network (NI) Loopback Network to CSU.Local CI Cha

Página 129 - (sysConfig x=1)

C100 and C150 Specifications6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUA-5Weight 9.70 lbs (4.40 kg)Mounting TabletopEnvironmentalOperating Temperatur

Página 130 - (chnConfig x=2)

C100 and C150 SpecificationsA-6 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99

Página 131 - —C150 only—

6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUB-1AppendixBSample ApplicationsThis appendix contains sample applications using the C100 and C150. Each ap

Página 132

Sample ApplicationsB-2 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99C100 T-1 Using V.35 Interfaces In Router ApplicationFigure B-1 depicts a typical ro

Página 133

Sample Applications6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUB-3Table B-1 Switches: C100/C150 CSU/DSUs connecting two LANs over T1/F-T1 S3 set us

Página 134

Sample ApplicationsB-4 Verilink C100 and C150 T1/FT1 CSU/DSU6/15/99T-1 C100/C150 CSU/DSU Connecting To A Frame Relay ServiceFigure B-2 shows the T-1 C

Página 135 - June 1999

Sample Applications6/15/99Verilink C100 and C150 T1/FT1 CSU/DSUB-5Table B-2 Switches: C100/150 T-1 CSU/DSU to Connect to a Frame Relay Service OFF S

Comentários a estes Manuais

Sem comentários