C100 and C150 SNMP MIB
6/15/99
Verilink C100 and C150 T1/FT1 CSU/DSUs
D-19
The following notes apply:
■
The dsx1LineStatus is a bit map represented as a sum; therefore, it
can represent multiple failures (alarms) and a LoopbackState
simultaneously.
■ dsx1NoAlarm should be set if and only if no other flag is set.
■
If the dsx1LoopbackState bit is set, the loopback in effect can be
determined from the dsx1LoopbackConfig object.
The following values are supported:
dsx1LineLength Object (dsx1ConfigEntry 6)
This variable controls the output power of the T-1 driver on the DSX1
interface. The following values are supported:
133 ft/0dB
266 ft
399 ft
533 ft
655 ft
-7.5dB
-15dB
-22.5dB
dsx1TrunkProcessing Object (dsx1ConfigEntry 7)
This variable represents the trunk processing control. The following
values are supported:
idle
busy
1 dsx1NoAlar No Alarm Present
2 dsx1RcvFarEndLOF Far end LOF (a.k.a., Yellow Alarm)
4 dsx1XmtFarEndLOF Near end sending LOF Indication
8 dsx1RcvAIS Far end sending AIS
16 dsx1XmtAIS Near end sending AIS
32 dsx1LossOfFrame Near end LOF (a.k.a., Red Alarm)
64 dsx1LossOfSignal Near end LOS
128 dsx1LoopbackState Near end is looped
256 dsx1T16AIS E1 TS16 AIS
512 dsx1RcvFarEndLOMF Far end sending TS16 LOMF
1024 dsx1XmtFarEndLOMF Near End Sending TS16 LOMF
2048 dsx1RcvTestCode Near End detects a test code
4096 dsx1OtherFailure Any line status not defined here