Verilink SCM (880-503300-001) Product Manual Manual do Utilizador Página 44

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 83
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 43
Administration Menu
4-6 Verilink SCM
This process requires you to have prior knowledge of the node
name and ID to in order to enter them correctly. After selecting “A”
in the SCM
Node Management Menu
you will be prompted:
Enter management node address #2:
Since the SCM already recognizes one node, the new node will
become #2 on the node list.
Discovery Option
Nodes are located using the node list configuration available on the
M1-3 and QUAD T1 modules. To access this option, go to the SCM
Controller
Main Menu
and select a module using the
S) shelf/slot
option. You will be prompted:
Enter 'shelf,slot' pair, or 'slot' in current shelf (e.g. 3,4 or 5):
In the sample node shown below, typing “4” accesses the QUAD T1
module. The
Main Menu
will appear with the QUAD T1 selected to
indicate that it is the module whose firmware is being accessed.
Figure 4-4 Main Menu with QUAD T1 Selected
With the QUAD T1 selected, type “R”. The
Data Link Layer Remote
Configuration
menu appears. In the sample in Figure 4-5, the
y/y
indicates that inband is enabled at both the local end and far end.
If the sample indicated
n/y
, this would signify that the local end is
disabled but the far end is enabled.
-- VERILINK SCM CONTROLLER : FW Rev 1.29, Nov 13 1998 16:53:13 --
-- VERILINK SCM CONTROLLER : FW Rev 1.29, Nov 13 1998 16:53:13 ---- VERILINK SCM CONTROLLER : FW Rev 1.29, Nov 13 1998 16:53:13 --
-- VERILINK SCM CONTROLLER : FW Rev 1.29, Nov 13 1998 16:53:13 --
Site name: SCM Tutorial Access level: 2
Site name: SCM Tutorial Access level: 2 Site name: SCM Tutorial Access level: 2
Site name: SCM Tutorial Access level: 2
Managing at NEAR end node [0.0.0.2] Node id: 122
Managing at NEAR end node [0.0.0.2] Node id: 122 Managing at NEAR end node [0.0.0.2] Node id: 122
Managing at NEAR end node [0.0.0.2] Node id: 122
<- SLOT ->
<- SLOT -> <- SLOT ->
<- SLOT ->
SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13
SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13 SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13
SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13
0 - - - - - - - - - - - - -
0 - - - - - - - - - - - - - 0 - - - - - - - - - - - - -
0 - - - - - - - - - - - - -
1 M *S D Q
1 M *S D Q 1 M *S D Q
1 M *S D Q [
[[
[Q
QQ
Q]
]]
] I M D - - - - - -
I M D - - - - - - I M D - - - - - -
I M D - - - - - -
2 - - - - - - - - - - - - -
2 - - - - - - - - - - - - - 2 - - - - - - - - - - - - -
2 - - - - - - - - - - - - -
3 - - - - - - - - - - - - -
3 - - - - - - - - - - - - - 3 - - - - - - - - - - - - -
3 - - - - - - - - - - - - -
4 - - - - - - - - - - - - -
4 - - - - - - - - - - - - - 4 - - - - - - - - - - - - -
4 - - - - - - - - - - - - -
KEY: D=QUAD D, I=IMUX, M=M1-3, Q=QUAD T1, S=SCM
KEY: D=QUAD D, I=IMUX, M=M1-3, Q=QUAD T1, S=SCMKEY: D=QUAD D, I=IMUX, M=M1-3, Q=QUAD T1, S=SCM
KEY: D=QUAD D, I=IMUX, M=M1-3, Q=QUAD T1, S=SCM
S) shelf/slot O) administration
S) shelf/slot O) administrationS) shelf/slot O) administration
S) shelf/slot O) administration
C) configuration D) diagnostics
C) configuration D) diagnosticsC) configuration D) diagnostics
C) configuration D) diagnostics
P) performance/status A) alarm
P) performance/status A) alarmP) performance/status A) alarm
P) performance/status A) alarm
B) circuit manager I) manufacturing info
B) circuit manager I) manufacturing infoB) circuit manager I) manufacturing info
B) circuit manager I) manufacturing info
R) remote end setup
R) remote end setupR) remote end setup
R) remote end setup
X) logoff
X) logoffX) logoff
X) logoff
A [0.0.0.2] [1,4] QUAD T1 >
A [0.0.0.2] [1,4] QUAD T1 >A [0.0.0.2] [1,4] QUAD T1 >
A [0.0.0.2] [1,4] QUAD T1 >
Vista de página 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 82 83