Verilink T1 ESF CSU (34-00309.B) Product Manual Manual do Utilizador Página 14

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 13
2
G
ENERAL
I
NFORMATION
Specifications
Network Interface
Line Rate:
1.544 Mbps (± 50 ppm)
Line Framing:
D4 or ESF
Line Code:
AMI or B8ZS
Line Impedance:
balanced 100
(± 5%)
Input Signal:
DS1, +1 to -30 dB (ALBO)
Output Signal:
3.0 V, ±15%, base-peak into 100
Line Build Out:
0,
7.5,
15, and
22.5 dB attenuation
Line Protection:
1000 V lightning, fused input and output
Jitter Control:
per TR 62411 and T1.403
Pulse Density:
per TR 62411
Equipment Interface
Line Rate:
1.544 Mbps (± 50 ppm)
Line Framing:
D4 or ESF
Line Code:
AMI or B8ZS
Line Impedance:
balanced 100
(± 5%)
Input Signal:
DSX1 to 655 feet
Output Signal:
Selectable DSX1 signal level from 0 to
655 feet
Line Protection:
1000 V lightning, input and output
Mechanical
Mounting:
desktop or wallmount
Dimensions:
1.25" H, 3.5" W, 5.75" D
Weight:
1 pound
Power Source
External:
Input: 115 VAC
Output: 9 VDC, 1.2 A
Industry Standards
FCC Compliance:
Part 15 Class A Subpart B, Part 68
Safety:
UL 60950
Industry Canada:
CS-03, Issue 8
Environmental
Operating Temp:
0° to 50°C (32° to 122°F)
Storage Temp:
20° to 70°C (
4° to 158°F)
Humidity:
95% max (non-condensing)
Vista de página 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 23 24

Comentários a estes Manuais