4-8 WANsuite 6x30
Sets the Errored Seconds threshold. An ES is a 1-second period in which at
least one logic error occurred. The default value is 45 seconds.
Sets the Severely Errored Seconds threshold.
which at least 320 Cyclic Redundancy Check (CRC) errors or one Out-of-
Frame (OOF) error occurred.
The default value is 5 seconds.
Sets the Loss of Signal Seconds threshold. A LOSS is a
which the T1 received signal is interrupted
. The default value is 5 seconds.
Sets the Unavailable Seconds threshold. A UAS is a
consecutive severely errored seconds cause an unavailable state
0 (zero) seconds (Disabled).
Sets the Controlled Slip Seconds threshold. The default is 0 (zero) seconds
Sets the Bipolar Violation Errored Seconds threshold. A BPVS is a 1-second
period in which at least one bipolar violation occurred. The default is 0 (zero)
Sets the Out-of-Frame Seconds threshold. An OOFS is a
which a frame sync loss occurred
. The default value is 5 seconds.
Sets the Alarm Indication Signal Seconds threshold. An AISS is a 1
period when unframed all ones are received.
The default is 0 (zero) seconds
Sets the Remote Alarm Seconds threshold.
A RAS is generated by the
terminal equipment when an improper signal is received from the facility (or
upon receipt of unframed all ones).
The default is 0 (zero) seconds (Disabled).
Sets the Reset Timer threshold. This field is the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of “000” means the
alarm will never be reset.
The Net Config screen provides the user-activated prompts described in the
CAUTION:
Performance data will be lost upon power cycle or after performing a
Maintenance Reset/Restart.
Resets the alarm conditions and counts to zero.
Displays a current count of the number of error events that have
occurred over the past 24 hours and the past 30 days.