4-16 WANsuite 6x30
Alarm Profile Details Screen
Select from the <Alarm Profiles> column on the above screen to display a
screen similar to the one shown in Figure 4.13. The table on this screen lets
you create/delete the associated entry in this table (profile name), and
configure the alarm threshold values to be used for the selected segment
Figure 4.13
Alarm Profile Details Screen
Displays the unique index associated with this Endpoint Alarm profile. A new
Alarm Profile can be created by entering a unique name for the profile in this
field and then, after configuring the desired alarm thresholds, pressing the
Sets the loop attenuation alarm threshold. If the current value reaches or drops
below this threshold, a crossing trap is generated.
Sets the Signal-to-Noise Ratio margin alarm threshold. When the current SNR
value reaches or drops below this threshold, a crossing trap is generated.
Sets the threshold for the number of Errored Seconds within any given 15-
minute performance data collection interval. If the value of ES in a particular
15-minute collection interval reaches/ exceeds this value, a trap is generated.
One trap will be sent per interval per endpoint.
Sets the threshold for the number of Severely Errored Seconds within any
given 15-minute performance data collection interval. If the value of SES in a
particular 15-minute collection interval reaches/exceeds this value, a trap is
generated. One trap will be sent per interval per endpoint.
Sets the threshold for the number of Cyclic Redundancy Check anomalies
within any given 15-minute performance data collection interval. If the value
of CRC anomalies in a particular 15-minute collection interval reaches/
exceeds this value, a trap is generated. One trap will be sent per interval per