Web Server Interface
network errored seconds in the previous 15 minutes reaches the preset
threshold for the specified error type, an alarm condition is declared.
The four columns of the status table are as follows:
The table provides error status and alarm threshold information for the
following error parameters:
Sets the Errored Seconds threshold. An ES is a 1-second period in which at
least one logic error occurred. The default value is 45 seconds.
Sets the Severely Errored Seconds threshold.
which at least 320 Cyclic Redundancy Check (CRC) errors or one Out-of-
Frame (OOF) error occurred.
The default value is 5 seconds.
Sets the Loss of Signal Seconds threshold. A LOSS is a
which the T1 received signal is interrupted
. The default value is 5 seconds.
Sets the Unavailable Seconds threshold. A UAS is a
consecutive severely errored seconds cause an unavailable state
0 (zero) seconds (Disabled).
Sets the Controlled Slip Seconds threshold. The default 5 seconds.
Sets the Bipolar Violation Errored Seconds threshold. A BPVS is a 1-second
period in which at least one bipolar violation occurred. The default is 0 (zero)
Sets the Out-of-Frame Seconds threshold. An OOFS is a
which a frame sync loss occurred
. The default value is 5 seconds.
Sets the Alarm Indication Signal Seconds threshold. An AISS is a 1
period when unframed all ones are received.
The default is 0 (zero) seconds
Sets the Remote Alarm Seconds threshold.
A RAS is generated by the
terminal equipment when an improper signal is received from the facility (or
upon receipt of unframed all ones).
The default is 0 (zero) seconds (Disabled).
Sets the Reset Timer threshold. This field is the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Displays the current status of the Network port.
Displays the alarm value of the Network port. The unit
declares an alarm as soon as the count exceeds the threshold
Displays the number of events or occurrences of this statistic
A read/write field that can be set to a desirable threshold.
Comentários a estes Manuais