Web Server Interface
3-45
Figure 3.43
Circuit Details Screen
Endpoint
Endpoint name. By default, the first circuit is always the LAN circuit. WAN
circuit endpoint names are taken from the VPI/VCI number. For example,
VPI 0/VCI 32 will have “P0-C32” for an endpoint name. The pull-down
menu will display a list of VPI/VCIs actually configured. A given circuit will
receive/transmit data on the VPI/VCI combination corresponding to its
endpoint name.
IP Address
IP Address of the circuit.
IP Mask
IP mask of the circuit.
Max Transmit Unit
Maximum transmit unit this circuit will send at any one time.
Cost
Represents the relative time of treatment of an IP packet. This value is used
when there are multiple routes to the same destination. When two or more
routes are available, the one with the lowest circuit cost is selected. An ATM
circuit should have a higher value than a LAN circuit.
RIP Status
Indicates whether or not RIP is enabled on this circuit.
Values:
Enable, Disable
Default:
Enable
Multicast Status
Indicates whether or not Multicast is enabled on this circuit.
Values:
Enable, Disable
Default:
Enable