
Web Server Interface
Alarm Profile Details Screen
Clicking on the “Alarm Profile Details” button displays the screen shown in
Figure 3.14. The table on this screen lets you create/delete the associated
entry in this table (profile name), and configure the alarm threshold values to
be used for the selected segment endpoint.
Figure 3.14
Alarm Profile Details Screen
Displays the unique index associated with this Endpoint Alarm profile. A new
Alarm Profile can be created by entering a unique name for the profile in this
field and then, after configuring the desired alarm thresholds, clicking on the
Sets the loop attenuation alarm threshold. If the current value reaches or drops
below this threshold, a crossing trap is generated.
Sets the Signal-to-Noise Ratio margin alarm threshold. When the current SNR
value reaches or drops below this threshold, a crossing trap is generated.
Sets the threshold for the number of Errored Seconds within any given 15-
minute performance data collection interval. If the value of ES in a particular
15-minute collection interval reaches/ exceeds this value, a trap is generated.
One trap will be sent per interval per endpoint.
Sets the threshold for the number of Severely Errored Seconds within any
given 15-minute performance data collection interval. If the value of SES in a
particular 15-minute collection interval reaches/exceeds this value, a trap is
generated. One trap will be sent per interval per endpoint.
Sets the threshold for the number of Cyclic Redundancy Check anomalies
within any given 15-minute performance data collection interval. If the value
of CRC anomalies in a particular 15-minute collection interval reaches/
exceeds this value, a trap is generated. One trap will be sent per interval per
Sets the threshold for the number of Loss of Sync Word Seconds within any
given 15-minute performance data collection interval. If the value of LOSW
Comentários a estes Manuais