VT100 Interface 4-19
Figure 4.16
Span Endpoint Maintenance Screen
The Span Endpoint Maintenance parameters are described below.
Specifies loopbacks for the associated segment endpoint.
No Loopback, Normal Loopback
Specifies the timeout value in minutes for loopbacks initiated at segments
endpoints contained in the associated unit. A value of 0 disables the timeout.
Indicates the state of the tip/ring pair at the associated segment endpoint.
Indicates the DC power source being used by the associated unit.
Enables the manager to trigger a soft restart of the SHDSL line at the
associated segment endpoint. The manager may only set this object to the
“restart” value to initiate a restart. The agent will perform a restart after
approximately 5 seconds, and restore the object to the “ready” state.
Selecting the “Performance” prompt on the Span Endpoint Details screen will
display the screen shown in Figure 4.17.